CPI Communications LE Series User Manual
Page 5
Table 4
3.3 Dip Switch Settings
Table 4 describes the functions provided by the dip switch on the bottom of the unit. The factory setting are
underlined.
3.4 Setting Levels
Receive audio is controlled via the front panel volume control. Handset audio for the LE10 is set via R28 on
the circuit board. It is factory set at mid range.
The transmit audio level is set via R44 on the circuit board. It should be set to provide the appropriate deviation
on the radio.
4.0 Parts List
LE series Bottom PCB #700-LEBB-200 revision C
Reference
Description
CPI Part #
CAPACITORS
C1,7,8,9,10,11,13,14,25
.1uF
208-0212-104
C2
22uF Electrolytic
208-4022-266
C4
47pF Mono Cer Dip
208-0071-470
C5
2200pF Mono Cer Dip
208-0071-222
C6,16
100uF Electrolytic
208-2021-107
C12
1uF Electrolytic Non-polar
208-2000-001
C15
10uF Electrolytic
208-2021-106
C17,18,20,23
220uF Electrolytic
208-2021-227
C19
4.7uF Electrolytic
208-4042-475
C22,29
.001uF Mylar
208-0212-102
C24
1000uF Electrolytic
208-1021-108
C27
100pF Mono Cer Dip
208-0071-101
C28
1uF Electrolytic
208-4052-105
C3,21
.01uF
208-0000-103
DIODES
D1,2,3,4,5,6,7,8,9
1N4148
212-0001-001
D10
1N4746
212-0100-019
D11,12,13,14
1N4004
212-0002-004
4
Switch #
ON
OFF
1
Low impedance load to radio RX out.
High impedance load to radio RX out.
2
OPTION - Latched F1/F2 output.
OPTION - Momentary F1/F2 output.
3
Monitor on front panel PTT.
Do not monitor on front panel PTT.
4
Speaker mute on any PTT.
Depends on setting of JP15.
5
Boosts level of parallel TX audio received.
Normal
6
Low impedance radio mic input.
High impedance radio mic input.
7
High level RX audio from radio.
Low level RX audio from radio.
8
For ground referenced RX audio from radio.
For non-ground reference RX audio from radio.