Analog Input Connector and Specifications (cont’d)

Figure 7

Input Resistance Schematic (Analog input: 0 – 5 VDC or 0 – 10 VDC)

RPM

4 - 20 (mA)

Input

resistance

490 ohms

(note 3,1,4)

0 - 5 (VDC)

(note 2,1)

0.5 - 10

(VDC)

(note 2,1)

Analog Input

Min

Max

Min Max Min Max Min Max

4 - 20 mA

0 - 5 VDC

0 - 10 VDC

Standard H Pump

6

750

1.6

20

0.2

5

0.2

10

See Waveforms 1 to 9

Standard Q Pump

600

Standard STQP

Pump

700

Table 2

Input Voltage/Current versus RPM

Note 1:

Maximum current is reduced provided control method is set according to actual

input method (ie 0 – 5 VDC or 0 – 10 VDC). If desired control method is set for

“4–20mA” but a 0 – 5 VDC or 0 – 10 VDC is applied the maximum current will be

at its greatest.

Note 2:

Absolute maximum input voltage is 10.8 VDC

Note 3:

Absolute maximum current is 22 mA

When start/stop is controlled via the analog input the pump(s) will stop when the analog input

goes below the minimum voltage/current. The pumps will run when the minimum voltage/current

is reached and will run at the minimum speed.

IN-PDS100-13A