Emergency emptying out

If the water is not discharged (pump is blocked, filter or drain hose are
clogged), proceed as follows to empty out the machine:

• pull out the plug from the power socket;

• close the water tap;

• if necessary, wait until the water has cooled;

• place a bowl on the floor;

• put the drain hose end into the bowl and let the water out.
Should it not be possible to have access to the drain hose because, for
example the appliance is built in the kitchen furniture, slightly loosen
the drain filter after placing a bowl on the floor to let the water come
out slowly.
At the end screw the filter again.

Frost precautions

If the machine is installed in a place where the temperature could drop
below 0°C, proceed as follows:

• Close the water tap and unscrew the water inlet hose from the tap.

• Place the end of the drain hose and the inlet hose in a bowl placed

on the floor.

• Select the “PUMP OUT” programme D and run it until the machine

stops.

• Turn the programme selector dial to RESET

O.

• Press the ON/OFF button

to switch the machine off.

• Remove the plug from the power socket.

• Screw the water inlet hose back on and put the drain hose back in its

place.

By doing this, any water remaining in the machine is removed, avoiding
ice forming and consequently damage to the appliance.
When you use the machine again, make sure that the ambient temper-
ature is above 0°C.