Katrina_540_color_pg4, V. wiring your valve & air source unit, You’re done – HornBlasters Admiral/Katrina 500 Series User Manual

Page 5

Advertising
background image

Safety Valve in Tank:

1. Install the safety valve into an available 1/2” port on the air tank using Teflon tape or pipe sealant on the threading of the

1/2” to 1/4” NPT F bushing. If the safety valve already has sealant on its threads, it is unnecessary to use Teflon tape on the

threads. Do not mount on bottom of tank, and do not use as drain.

4

Valve Wiring Flow Chart (Circuit 1)

[Factory Horn Wire] » [Toggle Switch) » [Air Valve] » [Ground]

V. Wiring Your Valve & Air Source Unit

Your train horn kit will use two completely independent circuits. One circuit will connect your horn trigger (push-button

switch, or toggled factory button) to your electric solenoid valve. The other circuit will connect your accessory trigger (ignition

wire, accessory wire) to your air source kit. If you have trouble with wiring, you can find a wiring diagram of your vehicle on

www.the12volt.com. This can help you locate certain wires to properly and safely install your train horn kit!

Circuit 1

1. Begin by wiring your horn trigger.

a. If you are intending to use your factory horn switch, start by locating the load wire of the horn button (positive

when horn button is depressed in a standard vehicle) and wiring it to the included toggle switch (any side).

b. If you are going to use a push button switch (intermittent toggle switch) wire a fused (5A) wire from any 12 volt

source desired (battery) to your switch (any side).

2. Wire your switch to any lead of your air valve.

3. Wire the other side of the air valve to ground.

4. Test your circuit by activating your trigger and listening for a quiet “click” sound from the valve.

Circuit 2

1. Find the accessory line in your vehicle (this is a wire that is only powered when the key is turned to the ‘accessory’ or ‘on’

positions.

2. Using the supplied 18 gauge wire connect the accessory wire to the “BLUE ignition positive wire” from the pressure switch.

3. Ground your pressure switch using the small “BLACK wire” from the pressure switch.

4. Locate your 12v DC power source that is capable of handling a 26 amp load.

5. Run the supplied 10 gauge or bigger wire to the inline fuse holder using the supplied 35 amp fuse. Then connect this to the

“RED fused 12v positive wire” from the pressure switch.

6. Connect the pressure switch to the air compressor using the “WHITE compressor wire” from the pressure switch to the “RED

wire” from the compressor.

7. Ground the other side of your air compressor using the “BLACK wire”.

8. Your compressor system will now turn on automatically when power is on (key is in ‘Accessory’ or ‘On’ position) and

automatically turn itself off upon reaching pressure limits.

You’re Done!

It’s time to test your horns! Share your install photos on our Facebook fanpage at www.facebook.com/hornblasters and don’t

forget to check out www.trainhornforums.com, the largest train horn community on the internet!

Air Gauge in Tank:

1. Install the Hornblasters Air Gauge into available 1/2” port on the air tank using Teflon tape or pipe sealant on the threading

of the 1/2” to 1/4” NPT F bushing. Make sure to mount the air pressure gauge on the side or the top of the tank so that

condensation will not be able to drain in to the gauge.