3

III. Installing Your Air Tank

Locate a secure area close to your air compressor to mount your air tank. The leader hose of the compressor
should be able to reach an available port on the air tank with some slack.

1. Position the tank in its desired location and secure it using standard mounting hardware.


IV. Installing Your Air Tubing & Air Valve

Before cutting any air tubing make sure to double check your measurements. Make sure to cut equal lengths of
air line to connect each horn to the splitter manifold or the horns may sound at different times. We recommend
cutting your lengths with at least an extra inch per line just to be safe. Compression fittings use ferrules (olives)
that should be used only once. The air valve should connect to the center

IMPORTANT: Do not rotate or remove the inline check valve in the compressor’s leader hose. Doing so will

damage its seals and will result in damage to your air compressor and voiding of your warranty.

IMPORTANT: Do not make any kinks in your air line. Doing so will disrupt air flow and is irreversible.

fitting of the 5-point splitter fitting.

When threading any fittings make sure to use Teflon tape or lock-tight to prevent air leaks.
The air valve may be mounted in any direction but it is preferred that it is mounted vertically.


Air Compressor to Tank:

[Air Compressor] » [1/4” Leader Hose] » [1/4 NPT Run Tee] » [1/4 NPT Port] » [Air Tank]
1. Install the 1/4 NPT brass run-tee in to an available port on your tank using Teflon tape or a locking

compound on the threads.

2. Next carefully connect the air compressor leader hose to the tank using the end port (the one that is

perpendicular to the original port) using Teflon tape on the threading. When installing the leader hose DO
NOT

3. Locate a secure location to mount the leader hose using the bracket provided. Avoid locations where the

leader hose may become tangled with wires and other hoses.

move the inline check valve located just above the swivel fitting.

a. When mounting the bracket drill a hole with a 3/16” drill bit and push the self-anchoring hose

bracket into the hole. Route the leader hose through the hose bracket and secure by pressing the
bracket clamp into the locker position.


Pressure Switch in to Tank:

[Air Tank] » [1/4 NPT Run Tee] » [1/4 NPT to 1/8 NPT Reducer Bushing] » [Pressure Switch Unit]
1. If you have not already done so, install the 1/4 NPT brass run-tee in to an available port on your tank

using Teflon tape or a locking compound on the threads.

2. Install the 1/4 to 1/8 NPT reducing bushing into the center port (port that is in-line with original tank port)

on the run-tee on the air tank using Teflon tape on the threading.

3. Install the pressure switch unit into the reducer bushing again using Teflon tape on the threading.


Air Horns to Tank:

[Air Tank] » [5/16” to 1/4 NPT M Fitting] » [5/16” Line] » [5/16” to 1/4 NPT M Fitting] »

[Air Valve] » [5/16” to 1/4 NPT M Fitting] » [5/16” Line] » [5/16” 5-point Splitter Fitting] »
[5/16” Line] » [5/16” to 1/8 NPT M Fitting] » [1/8 NPT F Elbow Fitting] » [Rear Horn Mount]

1. Plan out the fittings’ placement out before you begin and make sure you understand the correct order.
2. Make sure that your tank is empty of air and that the compressor is not running during installation.
3. Start by cutting equal lengths of 5/16” tubing to run from each horn to the 5-point manifold fitting.
4. Install the air line carefully using two wrenches for each compression fitting. Use one wrench to hold the

body of the fitting stationary and another to tighten the compression nut.

5. After plumbing the horns to their manifold fitting, measure and plumb one length of 5/16” tubing from the

center fitting of the manifold to the outlet of the air valve. If the valve has a directional arrow on its body
the arrow starts with the inlet and points out the outlet; the arrow should point towards your horns.

6. Next connect your air valve’s inlet port to your air tank using 5/16” air line using the 5/16” Straight to 1/4

NPT M fittings.