9. Troubleshooting Guide

9.4. Description of Alarm Codes

Item

Code (Hex)

Description

Same Code Over Count

0x01

Current position was detected after a fixed number of
trials. Check torque or control voltage.

Open Code Over Count

0x02

Open value was detected after a fixed number of trials.
Check connections between Bias-T, cable, and antenna.

Unknown Code Detection

0x04

Unknown position value was detected. Failure due to
motor box encoder inside antenna, Bias PCB, Bias-T, AD
converter of the controller, etc.

Maximum Limit Detection

0x08

Out of control range. Failure due to motor malfunction
or incorrect actuating voltage.

Minimum Limit Detection

0x10

Out of control range. Failure due to motor malfunction
or incorrect actuating voltage.

Next Code Not Detection

0x20

Control position failure. Failure due to insufficient
torque, motor encoder, etc.

Miss Path Detection

0x40

Failure in control path relay, controller, incorrect position
of motor during antenna assembly, etc.


Note: The above alarms include failures that may not be repaired by end-users. Contact KMW
Technical Support for further assistance.

9.5. General Information

• PAC reset while operating:

This may be caused by insufficient amount of remaining battery power. Check the battery level
and recharge if necessary.

• Recovering from Alarm:

For any alarms listed above (Table 6-1), the PAC automatically recovers from the alarm. If an
alarm continues to appear, user may try to recover from the alarm by pressing ‘ENT’ key after
alarm appeared. If the alarm continues after the manual recovery process, contact KMW Technical
Support for further assistance.