NOTE: If after calibration your scale does not read accurately, this indicates

calibration error and the calibration process should be repeated more slowly.

Please calibrate on a very stable flat surface!

INACCURACY/ERROR

The primary reasons for inaccuracy or malfunction are low batteries, incorrect

calibration, overload or operating on an unstable/non level surface. Please keep
this in mind and maintain and operate your scale properly. The scale is a precise
instrument and must be handled with the utmost care and caution.

FEATURE
¾

Power Up Segment Test

When first powering the scale on, all segments of the display will appear from

“99999” to “00000”.
¾

Overload

When an applied load exceeds the maximum capacity. It will display “- - - - -“,

Remove the excessive load immediately!

Remember: You can permanently damage the scale by overloading it!

¾

Negative Value

Any tared value or a value left in memory will be displayed as a negative

number once all weight is removed from the tray. Press TARE to re-Zero the

mode.

4.


KEY PAD FUNCTIONS

‹

MODE

MODE(mode) selection: Press and release the MODE key once to change the
weight mode. You can select g (grams), kg (kilograms), lb (pounds) oz (ounces)
or lb/oz (pounds/ounces).

ƒ

: Power switch

Press this key to turn mode on. Once the mode is on, press and hold the

same key to turn the scale off.

ƒ

HOLD

Press this key to hold current weight reading, press again to cancel.

ƒ

TARE : Zero or tare

Press TARE to reset the scale to zero the scale or to tare off the weight of a

container. When the scale is in TARE mode (for larger weights that are tared

off) The tare indicator will appear and the display will show “0”.

Backlight switch

On the back of the scale, next to

the AC socket is the backlight switch.

Slide it to enable or disable the

backlight.

Buzzer / Beep Function

On the back of scale, the other

switch is the Beep switch, Slide it to

enable or disable the beeper.

AC ADAPTOR

The scale can be operated on AC power with the standard KD7000 AC

adaptor whose output is DC 4.5 ~ 6 volt.

NOTE: Please only use the correct AC adaptor for this scale – an incorrect AC

adaptor can cause damage to the scale and possible fire or injury. Use of an

incorrect AC adaptor will also void your warranty.

2.

KD-7000 Manual

Precautions Before Using The Scale

The scale should always be used in a stable environment without excessive

air currents, corrosives, vibrations, and extremes in temperature or humidity.
These factors can affect the accuracy and performance of the scale.

Scale Operation Notes

ƒ

Do not Overload (exceed the capacity) of the scale including the weight of any

trays or bowls combined with objects you may be weighing. Overload or

Dropping/shocking the scale will damage the sensor and void your warranty.

ƒ

Allow sufficient warm up time. Turn the scale On and wait several seconds to

give the internal components a chance to stabilize before weighing.

ƒ

The cleaner the environment the better. Dust, dirt, moisture, vibration, air

currents and proximity to other electronic equipment can all cause an adverse

effect on the reliability and accuracy of your scale.

ƒ

Handle with care. Gently apply all items to be weighed onto the tray. Although

this scale is designed to be quite durable, avoid rough treatment as this may

permanently damage the internal sensor and void your warranty.

ƒ

Avoid lengthy exposure to extreme heat or cold, your scale works best when

operated and stored at normal room temperature.

ƒ

Place the item to be weighed on the platform, after the stable weight is displayed

remove the item immediately. This will prolong the longevity and accuracy of this

weighing instrument.

Turn on The Scale

Press to turn on the scale. The scale will go through a quick warm up

procedure and self test. It will show “0” on the display and be ready for use.

Display Widow

HOLD: Current weight reading is held. : Current reading is stable.

: Scale is in Zero mode. : Scale is in TARE mode.

: Battery is at low voltage or under heavy load.

1.

OPERATION

Battery Operation:


1)

Three “AA” size ALKALINE batteries (1.5V*3) are required.

2)

To install batteries:
a) Open

the

battery

cover.

b)

Place batteries into battery compartment aligned correctly.

c)

Replace battery cover.

3)

The scale is now ready for battery operation.

WEIGHT RESPONSE SPEED & AUTO TURN OFF

Hold the HOLD key (don’t release), then press and release the Power key. Wait

5 seconds. Press MODE to scroll from “nb0” to “nb2” (nb0 is slowest), press

TARE for confirmation. The display will show “OFF 0” (disabled) or “OFF 1”

(automatic turn off after about 2 minutes) or “OFF 2” (automatic turn off after

about 5 minutes), select the auto turn off time by pressing MODE, confirm it by

pressing TARE. The scale will return to the normal weighing mode.

(Advanced users only) CALIBRATION

IMPORTANT: This scale was professionally factory calibrated before shipment. It

does NOT need to be recalibrated before use and will not usually require

calibration during its lifetime. However some advanced users who seek optimum

accuracy may wish to calibrate the scale periodically to maintain perfect

accuracy. Incorrect calibration can occur if you do not follow the steps exactly.

You will need a 5kg weight to calibrate this scale.

1)

Turn the scale OFF and place it on a FLAT, very stable surface .

2)

Press and hold MODE and to turn on the scale, wait for the display

to show “CALE”.

3) Place a 5kg weight on the tray, wait 3 seconds then press TARE.

Calibration is complete.