Note: Special consideration is to be observed with the active mat
connector. The design of this component is that it will "free float" when
pressure is applied. Alignment of the through holes of the rail and anchor
is such that no binding is allowed. Over torque will activate the mat.

The edging strips have been grooved according to the installation drawing to allow
accommodation for the lead wire. Important – If the edging is used in a different
manner, a groove MUST BE cut in the edging where it lies over the lead wire. The leads
must not have any undue pressure applied to them, as this will cause mat failure. Also, it
is recommended that the leads from each mat be held to a minimum length of 2 feet each.

Care of the Switchmat lead wire(s)

Lead wire(s) must be routed to prevent damaging insulation or breaking internal wires.