Type of gas – American Dryer Corp. MDG75V User Manual

Page 30

Advertising
background image

26

2. Technical Gas Data

a. Gas Specifications

b. Gas Connections

Inlet connection ------------------- 3/4” N.P.T.
Inlet supply size ------------------- 3/4” N.P.T. (minimum)
Btu/hr input (per dryer) ---------- 175,000 (44,100 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.

* Drill Material Size (D.M.S.) equivalents are as follows:

Natural Gas ........................ #30 = 0.1285” (3.2639 mm).
L.P. Gas ............................. #49 = 0.0730” (1.8542 mm).

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

Shaded areas are stated in metric equivalents

* Measured at outlet side of gas valve pressure tap when gas valve is on.

TYPE OF GAS

Liquid Propane

Conversion Kit

Part Number

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty.

D.M.S.*

Part

Number

Qty.

D.M.S.*

Part

Number

MDG75V

175,000

44,100

4

#30

140819

4

#49

140803

883329

Shaded area is stated in metric equivalent