Operating instructions

5

2

S

AFETY DEVICES

DO NOT ALTER THE SAFETY DEVICES AND DO NOT UTILIZE THE MACHINE IF THE SAFETY DEVICES ARE
DAMAGED OR MALFUNCTIONING.

THE MANUFACTURER IS NOT RESPONSIBLE FOR POSSIBLE DAMAGES CAUSED TO PEOPLE OR OB-
JECTS BY THE ALTERING OR BYPASSING SUCH DEVICES OR RELATIVE CIRCUITS.

2.1

Lid's magnetic sensor

This safety device, featuring an approved type magnet [1] and a magnetic contact [2]
avoids accidents caused by the accidental starting of the beater when the lid is open. In
consequence the device can't operate when the lid is open, and if it is opened during its
functioning the beater immediately stops.

In any case the lid's magnetic sensor MUST NOT be considered a control to be used for
the normal stop of the device.

DURING THE NORMAL USE, THE DEVICE MUST BE STOPPED ONLY BY
USING THE BUTTONS ON THE CONTROL KEYPAD, AND NOT BY OPEN-
ING THE LID.

The magnet [1] and the magnetic contact [2] must be assembled as follows: the grooves [3] and the stencilled semicircle [5]
on the bottom of the magnet [1] must coincide with the grooves [4] (marked by a white line down the side) and the stencilled
semicircle [6] on top of the magnetic contact [2]. The device will not work unless all parts have been correctly
assembled in accordance with these instructions.

3

T

ECHNICAL DATA

3.1

Technical data plate and CE marking

The technical data plate and CE marking must not be removed. It is placed on the back side of the device and identifies:

-

the name and address of the manufacturer [1];

-

the designation of the model [2];

-

the relative serial number [3] and the year of construction [4];

-

the values of voltage and frequency [5];

-

the type of cooling [6], the power [7] and current [8] consumption;

-

the type and quantity of freezing gas contained [9];

-

the values of high and low pressure [10] and the CE marking [11].

3.2

Acoustic pressure level

The average equivalent continuous acoustic pressure level of this device is quoted in the Technical Handbook (Technical
Data section). This data has been measured at 1 meter from the surface of the device and at 1.60 meters from ground-
level, during the device’s functioning.