American Standard Whirlpool/Bathing Pool 2645 Series User Manual

Installation instructions, Whirlpool/bathing pool 2645 series, Scala™ 5-1/2

Advertising
background image

750733-100 Rev. F

INSTALLATION INSTRUCTIONS

SCALA™ 5-1/2

WHIRLPOOL/BATHING POOL

2645 SERIES

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard nc un ess otherwise noted

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

T H A N K Y O U . . .

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.

To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any
shipping damage. If such damage is found, report it to
your vendor immediately.

After inspection and during installation, protect the bath
from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit
and check for leaks.

If a whirlpool, do not make modifications to the whirlpool
system or remove pump from factory mounting. This
could adversely affect the safety and performance of the
whirlpool and void the warranty. Do not handle or move
the whirlpool by the pump, motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided
with the bath and must be ordered separately. Framing
and enclosing materials are provided by others. Check
for availability of optional American Standard wall tiling
bead (required for recess installations).

Protect all finished surfaces of the whirlpool during
construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping har-
ness at any time.

List of Optional Components (not included):
• Apron Kit*
* see your American Standard Distributor

List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun

Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp
GFCI Outlet
• Cement, Plaster,
Grout

C/L OF
DRAIN

1676mm

(66)

6mm

(1/4)

TYP.

25mm (1)

TYP.

302mm

(11-7/8)

PROVIDE ACCESS

TO PUMP FOR

SERVICING ON ALL

INSTALLATIONS

914mm

(36)

51mm
(2)

HAND SHOWER
LOCATION

RECOMMENDED FITTING LOCATION

64 X 330mm (2-1/2" x 13")

OUTLINE OF CUTOUT

1626mm X 864mm

(64 X 34)

419mm

(18)

44mm

(1-3/4)

210mm

(8-1/4)

ON/OFF

SWITCH

PUMP

229mm X 305mm
(9 X 12) CUTOUT
FOR DRAIN

1-1/2 O.D. TAILPIECE

1-1/2 N.P.T.M. THREADS

INTEGRAL

FEET SUPPORT

502mm

(19-3/4)

464mm

(18-1/4)

457mm

(3-5/8)

44mm
(1-3/4)

38mm

(1-1/2)

102mm
(4)

LEVELING STRINGER

(NOT FOR SUPPORT)

66 x 36 x 19-3/4 In. (1676 x 914 x 502mm)

95 Lbs. (43 Kg.)

595 Lbs. (268 Kg.)

60 Gal. (227 L)

55 Gal. (208 L)

46 x 24 In. (1168 x 610mm)

62 X 31-1/2 In. (1575 x 800mm)

13-1/4 In. (337mm)

36 Lbs./Sq.Ft. (175 Kgs/Sq.m)

25.6
45.1

GENERAL SPECIFICATIONS FOR 2645 WHIRLPOOL

1.1 HP, 9.9 AMPS,120V.

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)