Technical data, Installation instructions, Dimensions – Aga Ranges Legacy 44 User Manual

Page 46: Connections, Ratings

Advertising
background image

46

Read all instructions before installing or using this appliance.

Installation Instructions

Save these instructions for future reference.

Technical Data

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION: Inside base of drawer cavity - remove drawer. For removal of drawer see installation
instructions.

Dimensions

Overall height (splash not fi tted)

minimum

35 /’’

(89.8 cm)

maximum 36 /” (92.5 cm)

Overall width

43 /’’

(110cm) See ‘Positioning the Range’

Overall depth without spacer

26 ¾” (68cm).

Overall depth with spacer

28 ¾” (73cm)

Space for fi xing

See ‘Positioning the Range’

Minimum space above cooktop

30” (76cm)

Connections

Electric:

208 - 240 V 60 Hz (120volt oven lights / 120volt neons)

Ratings

Ovens

Left hand Multifunction Oven

Right hand Fan Oven

Fan element

2500W

2500W

Top element

1200W

Browning Element

1150W

Bottom element

1000W

Broiler

2300W

Maximum total electrical load at 240V

16700W (approximate total including oven lights, oven fan etc.)

Recommended power cord rating 50 ampere in line with Nation Electrical code ANSI/NFPA 70

Total current draw approximately 69.6A