Straight-through wiring, Crossover wiring, Table b-1 – Accton Technology ES3628EA User Manual

Page 48: 10/100base-tx mdi and mdi-x port pinouts, Figure b-2

Advertising
background image

B-2

Cables

B

Straight-Through Wiring

If the twisted-pair cable is to join two ports and only one of the ports has an internal
crossover (MDI-X), the two pairs of wires must be straight-through. (When
auto-negotiation is enabled for any RJ-45 port on this switch, you can use either
straight-through or crossover cable to connect to any device type.)

We recommend connecting all four wire pairs as shown in the following diagram to
ease a future upgrade to Gigabit Ethernet.

Figure B-2 Straight-through Wiring

Crossover Wiring

If the twisted-pair cable is to join two ports and either both ports are labeled with an
“X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be
implemented in the wiring. (When auto-negotiation is enabled for any RJ-45 port on
this switch, you can use either straight-through or crossover cable to connect to any
device type.)

We recommend connecting all four wire pairs as shown in the following diagram to
ease a future upgrade to Gigabit Ethernet.

Table B-1 10/100BASE-TX MDI and MDI-X Port Pinouts

Pin

MDI Signal Name

MDI-X Signal Name

1

Transmit Data plus (TD+)

Receive Data plus (RD+)

2

Transmit Data minus (TD-)

Receive Data minus (RD-)

3

Receive Data plus (RD+)

Transmit Data plus (TD+)

6

Receive Data minus (RD-)

Transmit Data minus (TD-)

4,5,7,8

Not used

Not used

Note: The “+” and “-” signs represent the polarity of the wires that make

up each wire pair.

White/Orange Stripe

Orange

White/Green Stripe

Green

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

EIA/TIA 568B RJ-45 Wiring Standard

10/100BASE-TX Straight-through Cable

End A

End B

Blue

White/Blue Stripe

Brown

White/Brown Stripe

Advertising