Axw-avt, Ax-dv ax-dm or ie/if-series audio door station, Afi mt-1890 – Aiphone AXW-AVT User Manual

Page 7

Advertising
background image

CONFIGURATION DIAGRAM:
AXW-AVT / AXW-AVR with AFI (American Fibertek) Fiber (MT-/MR-1890), 1 of 2

Pg. 11

Pg. 12

CCTV Camera
75 Ohm, 1V Peak-to-peak
(Independently powered)

Normally Closed input for remote activation

(i.e. motion sensor, loop detector, etc.)

Normally Open contact for remote device activation

(i.e. video switcher, DVR, etc.)

AXW-AVT

24V

+

-

RELAY

NO
NO

SENSOR

NC
NC

CALL IN

+

-

CALL OUT

+

-

AUDIO IN

+

-

AUDIO OUT

+

-

DOOR

VIDEO IN

VIDEO OUT

AX-DV

AX-DM or IE/IF-Series

Audio Door Station

CAT-5e

Coax

*

+

-

PS-2420UL

Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3

rd

party devices interfacing with it are included here. Aiphone is not

responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3

rd

party transmission hardware. Consult the installation manual for the 3

rd

party device being utilized

for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http://
www.aiphone.com or contact Aiphone Technical Support.

For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
available at http://www.aiphone.com).

Optic Fiber

(to MR-1890, Pg. 13)

Configuration Notes (1 of 2):
1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure

that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position.

*2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with

3

rd

party CCTV camera. Connect audio door station to ‘Door’ input (following

the wiring method shown in the AX-series installation manual, pg. 12).
Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the
‘CCTV’ position.

3. Connect the Call In / Call Out and Audio In / Audio Out connections on the

AXW-AVR to the terminal block of the AFI MT-1890, as shown. For detailed
terminal definitions, consult the AFI MT-1890 installation sheet.

Configuration Notes (1 of 2, continued):
4. When the SENSOR input is used, the door

station will be turned on whenever the sensor
device is activated (Normally Closed contact
from 3

rd

party supplied device).

5. The RELAY output provides an optional

Normally Open dry contact output which is
activated whenever the AX-series door station
is in use. This can be used to activate any
device local to the AXW-AVT (DVR trigger,
video switcher activation, local call indication,
etc.).

6. Configure AXW-AVT internal jumpers as

necessary (see Pg. 21).

24VAC

Coaxial Video Cable

AFI MT-1890

To AFI-specified /supplied

power source

**The AFI MT-1890 provides only a single relay output, which may be used to control the door
station’s standby mode (when connected to the ‘Call Out’ terminals on the AXW-AVT), or for door
release. If utilized for door release, ensure that the ‘Call Out’ terminals on the AXW-AVT are
shorted together. Note: This will cause the door station to be in a constant-on state, which
may reduce the lifespan of the AX-series door station.

**

**