Electrical Requirements

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.

GROUNDING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an
equipment-grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.

WARNING:

Improper connection of the

equipment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service
representative or personnel if you are in doubt as to
whether the dryer is properly grounded. Do not modify the
plug provided with the dryer: if it will not fit the outlet, have
a proper outlet installed by a qualified electrician.

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 mm) water
column.

Examples of a qualified person include:

licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Gas Type

Natural gas:

This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.

Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate
in the door well of your dryer. If this information does not
agree with the type of gas available, contact your dealer or
call the phone numbers referenced in the “Assistance or
Service” section.

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.

Gas supply line

Must include

1

/

8

" NPT minimum plugged tapping accessible

for test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).

½" IPS pipe is recommended.

3

/

8

" approved aluminum or copper tubing is acceptable for

lengths under 20 ft (6.1 m) if local codes and gas supplier
permit.

If you are using Natural gas, do not use copper tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.