Lenovo ThinkServer RD210 User Manual

Rack, Installation, Instructions

Advertising
background image

Rack

installation

instructions

Review

the

documentation

that

comes

with

the

rack

cabinet

for

safety

and

cabling

information.

Before

you

install

the

server

in

a

rack

cabinet,

review

the

following

guidelines:

v

Two

or

more

people

are

required

to

install

the

device

in

a

rack

cabinet.

v

Make

sure

that

the

room

air

temperature

is

below

35°C

(95°F).

v

Do

not

block

any

air

vents;

usually

15

cm

(6

in.)

of

space

provides

proper

airflow.

v

Do

not

leave

open

spaces

above

or

below

an

installed

server

in

your

rack

cabinet.

To

help

prevent

damage

to

server

components,

always

install

a

blank

filler

panel

to

cover

the

open

space

and

to

help

ensure

proper

air

circulation.

v

Install

the

server

only

in

a

rack

cabinet

with

perforated

doors.

v

Plan

the

device

installation

starting

from

the

bottom

of

the

rack

cabinet.

v

Install

the

heaviest

device

in

the

bottom

of

the

rack

cabinet.

v

Do

not

extend

more

than

one

device

out

of

the

rack

cabinet

at

the

same

time.

v

Remove

the

rack

doors

and

side

panels

to

provide

easier

access

during

installation.

v

Connect

the

server

to

a

properly

grounded

outlet.

v

Do

not

overload

the

power

outlet

when

you

install

multiple

devices

in

the

rack

cabinet.

v

Install

the

server

in

a

rack

that

meets

the

following

requirements:

Minimum

depth

of

70

mm

(2.76

in.)

between

the

front

mounting

flange

and

inside

of

the

front

door.

Minimum

depth

of

157

mm

(6.18

in.)

between

the

rear

mounting

flange

and

inside

of

the

rear

door.

Minimum

depth

of

718

mm

(28.27

in.)

and

maximum

depth

of

762

mm

(30

in.)

between

the

front

and

rear

mounting

flanges

to

support

the

use

of

the

cable-management

arm.

Use

safe

practices

when

lifting.

18

kg

(39.7

lb)

32

kg

(70.5

lb)

55

kg

(121.2

lb)

Do

not

place

any

object

on

top

of

rack-mounted

devices.

Notes:

1.

Cage

nuts

and

clip

nuts

are

not

required

to

install

the

server

in

a

rack

cabinet.

2.

You

can

install

the

cable-management

arm

on

either

side

of

the

server.

The

installation

instructions

in

this

document

can

be

reversed

if

you

are

installing

the

cable-management

arm

on

the

side

of

the

server

not

shown.

The

following

illustration

shows

the

items

that

you

need

to

install

the

server

in

the

rack

cabinet.

If

any

items

are

missing

or

damaged,

contact

your

place

of

purchase.

Advertising