S P E C I F I C A T I O N S

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE: The

cross-flow heat recovery core transfers heat between the two air

streams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS: Each air stream has one centrifugal blower

driven by a common PSC motor. 120 VAC, 1.4 Amps.
FILTERS: Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV: Four 10-24 5/8” threaded inserts at corners of

case designed to accept four PVC reinforced polyester straps that are sup-

plied with the unit.
DEFROST: Damper defrost system; defrosts automatically as the out-

door temperature falls.
CASE: Twenty gauge prepainted galvanized steel (G60) for superior

corrosion resistance. Insulated to prevent exterior condensation. Drain

connections 2 - 1/2” (12 mm) OD.
WEIGHT: 71 lbs. (32.5 kg) SHIPPING WEIGHT 73 lbs. (33.5 kg)
CONTROLS: Basic ON/OFF control is maintained with the 3 foot,

120VAC, 3-prong electrical cord providing power to the HRV.
HRV DEFAULTS TO LOW SPEED when plugged in. HIGH SPEED op-

tion is accessible by connecting remote, low voltage, 2-wire controls (up

to 10) or (up to four 28 884 -20 minute fan timers) to designated terminals

inside electrical box of HRV.
STANDARD SPEED SETTING can be increased by manipulating jump-

ers in electrical box. OFF (Standby) /LOW or OFF/HIGH speed opera-

tion also available by manipulating jumpers.
OFF, LOW and HIGH speeds are all remotely controllable when an op-

tional 28 883 Dehumidistat Ventilation Control (DVC) is connected to the

HRV’s electrical box.

APPROVALS: SAFETY: ETL Tested / Certified to UL 1812

CSA

PERFORMANCE: HVI Tested / Certified to CSA 439-88

P E R F O R M A N C E

HVI CERTIFIED

Net Supply airflow in cfm (L/s) against external static pressure

E .S .P .

LLLLLTTTTT-15

-15

-15

-15

-15

[cfm (L/s) ]

LLLLLTTTTT-20

-20

-20

-20

-20

[cfm (L/s) ]

0.1" (25 Pa)

177 (83)

214 (101)

0.2” (50 Pa)

164 (77)

206 (97)

0.3” (75 Pa)

156 (73)

193 (91)

0.4” (100 Pa)

143 (67)

184 (87)

0.5” (125 Pa)

123 (58)

170 (80)

Max. Sensible Effectiveness

78%

69%

Test Parameters 67 cfm (32 L/s) 127 cfm (60 L/s)

Sensible Effectiveness

76%

67%

Sensible Efficiency
@ 32° F ( 0° C )

66%

60%

Sensible Efficiency
@ -13° F ( -25° C )

60%

59%

VAC @ 60HZ

120

120

WATTS / High @ .3" w.c. 173

182

WATTS / High @ .3" w.c. 63

70

OPTIONS

28 884 20 Minute Fan Timer (3 wire)

28 998 Sixty Minute Remote Timer (2 wire)

28 883 Dehumidistat Ventilation Control, Remote

Dehumidistat w/ HRV system on/off switch

28 882 Dehumidistat Control, Remote Wall Mount,

Horizontal Mounting, Low Voltage white)

22 026 Weatherhoods, 6” (150 mm) c/w 1/4’ (6 mm) screen

All units conform to

CSA and UL

Standards

WARRANTY

Units carry a 15

year warranty on

the heat recovery
core and a 2 year

replacement parts

warranty.

CONDENSATE DRAINS