Power management options, Table 1.6: power management options – Avocent 5240 User Manual

Page 21

Advertising
background image

Chapter 1: Introduction 9

Power management options

Table 1.6 shows the power management option names and command names used when you are
logged into the Web Manager, when you have selected a target device from the spshell menu on the
MergePoint 5224/5240 SP manager console and when you are entering the ssh command on a
remote workstation. The power management options are only available for managed servers with
SPs.

The effects of the SP power management commands differ from one vendor’s SP to another. Table
1.8 describ
es the options. If an SP provides more than one of the options shown, the hard power
option is performed.

See Power Management Options on page 19 for an overview of all the types of power management
that users can perform.

Table 1.6: Power Management Options

Method

Option or Command Name Action

Web Manager

Power On

Power Off

Power Cycle

Power Status

Turn power on

Turn power off

Power cycle

Check power status

spshell menu in the
MergePoint 5224/5240 SP
manager console

Manage power

Brings up a menu of power management options

Turn power on

Turn power off

Turn power off then on

Get power status

ssh command

power

Power management options are performed using
the following power management commands

poweron

poweroff

powercycle

powerstatus

Table 1.7: Possible Power Management Command Effects

Power Command

Option

Power off

Hard power off: remove the power

Soft power off: shut down the operating system before removing the power

Power cycle (turn power off,
then on again, to reboot
the server)

Hard power cycle: remove the power, wait several seconds and then turn the
power on again (to reboot the server)

Soft power cycle: shut down the operating system, wait several seconds and
then turn power on again

Advertising
This manual is related to the following products: