0270*

Real

time

clock

error

Real-time

Clock

fails

BIOS

hardware

test.

May

require

board

repair.

0271

Check

date

and

time

settings

BIOS

found

date

or

time

out

of

range

and

reset

the

Real

-Time

Clock.

May

require

setting

legal

date

(1991-2099).

0280

Previous

boot

incomplete

-

Default

configuration

used

Previous

POST

did

not

complete

successfully.

POST

loads

default

values

and

offers

to

run

BIOS

Setup

Utility.

If

the

failure

was

caused

by

incorrect

values

and

they

are

not

corrected,

the

next

boot

will

likely

fail.

On

systems

with

control

of

wait

states,

improper

BIOS

Setup

Utility

settings

can

also

terminate

POST

and

cause

this

error

on

the

next

boot.

Run

BIOS

Setup

Utility

and

verify

that

the

wait-state

configuration

is

correct.

This

error

is

cleared

the

next

time

the

system

is

booted.

0281

Memory

Size

found

by

POST

differed

from

CMOS

Memory

size

found

by

POST

differed

from

CMOS.

02B0
02B1

Diskette

drive

A

error

Diskette

drive

B

error

Drive

A:

or

B:

is

present

but

fails

the

BIOS

POST

diskette

tests.

Check

to

see

that

the

drive

is

defined

with

the

proper

diskette

type

in

BIOS

Setup

Utility

and

that

the

diskette

drive

is

attached

correctly.

02B2

Incorrect

Drive

A

type

-

run

SETUP

Type

of

diskette

drive

A:

not

correctly

identified

in

BIOS

Setup

Utility.

02B3

Incorrect

Drive

B

type

-

run

SETUP

Type

of

diskette

drive

B:

not

correctly

identified

in

BIOS

Setup

Utility.

02D0

System

cache

error

-

Cache

disabled

RAM

cache

failed

and

BIOS

disabled

the

cache.

On

older

boards,

check

the

cache

jumpers.

You

may

have

to

replace

the

cache.

See

your

dealer.

A

disabled

cache

slows

system

performance

considerably.

02F0

CPU

ID

CPU

socket

number

for

Multi-Processor

error.

02F4*

EISA

CMOS

not

writable

ServerBIOS2

test

error:

Cannot

write

to

EISA

CMOS.

02F5*

DMA

Test

Failed

ServerBIOS2

test

error:

Cannot

write

to

extended

DMA

(Direct

Memory

Access)

registers.

02F6*

Software

NMI

Failed

ServerBIOS2

test

error:

Cannot

generate

software

NMI

(Non-Maskable

Interrupt).

02F7*

Fail

-

Safe

Timer

NMI

Failed

ServerBIOS2

test

error:

Fail-Safe

Timer

takes

too

long.

Solving