5-4

5.1

Both Sides Adjustment

F

Press [Exit Print Mode].

G

Measure a gap between the front and
back sides at each point of [a] to [d] on
the [back] side of the printed out chart.

-

This figure shows an example to measure [a].
The scale resolution is 0.5 mm.

-

In this figure, the black line indicates the front
side, and the blue line indicates the back
side.

-

The measurement value can be entered in
units of up to 0.1 mm.

-

For example, as shown in the figure, if the
scale of [a] is misaligned 1.5 mm in the plus
side compared with the front side, press [1] -
[5] - [+/-] to enter "-1.5" as the adjustment
value. Then, the blue line on the back side
will be moved 1.5 mm in the minus side.

-

Write down the measured values so that you
do not forget them.