Arcam A85 User Manual

Page 7

Advertising
background image



SK103 connects to the micro controller and display PCB.
The 14 pin connector is numbered as follows:

No Name

Type Description

1

+5V_D

O/P

5 volt digital supply (for micro)

2 0V_D

O/P Digital

ground

3

+49V

O/P

Main power supply for VFD (via fusible resistor)

4

STANDBY

I/P

Mains relay control signal

(HIGH = ON)

5

SPKR1 ON

I/P

Speaker 1 relay control signal

(HIGH = ON)

6

SPKR2 ON

I/P

Speaker 2 relay control signal

(HIGH = ON)

7

THERMPROT

O/P

Over temperature protect

(HIGH = FAULT)

8

VIPROT

O/P

Short circuit protect

(HIGH = FAULT)

9

DCPROT

O/P

DC offset protect

(HIGH = FAULT)

10

AC PRESENT

O/P

Indicates AC mains is plugged in

(HIGH = ON)

11

TRIGGER

O/P

12V DC trigger input

(HIGH = ON)

12

REMOTE

O/P

Demodulated RC5 remote input from rear panel

13

0V_D

O/P

Spare digital ground pin

14

+5V_D

O/P

Spare 5 volt digital supply pin



The ground naming convention is as follows:

Name Description

0V_D

Digital ground (used for micro processor circuitry, display and interface)

0V_LS_R

Right channel loudspeaker ground return

0V_SIG

Signal ground (this is the ‘clean’ precision reference ground)

0V_PSU

Power supply ground (high current pulses for the large reservoir caps)

0V_TRIG

Ground return for the jack socket trigger and remote control circuit

0V_HF_R

Decoupling ‘noisy’ ground for the right channel power amp

0V_LS_L

Left channel loudspeaker ground return

0V_HF_L

Decoupling ‘noisy’ ground for the left channel power amp

Advertising