background image

bizhub PRESS C1070/C1070P/C1060

2-4

2.2

Installation Procedures

2

5

Pull out the fixing plate [1] forward.

6

Holding the handles on the rear and front sides [2] of the fus-
ing unit [1] by both hands, slide the fusing unit [1] forward to
the position of arrow mark.

Please be careful when working on the fusing unit; the unit is
extremely hot.

7

Holding the handles on the rear and front sides [2] of the fus-
ing unit [1] by both hands, remove the fusing unit [1].

Place the removed fusing unit on the flat surface.

8

Holding the handles on the front and rear sides [2] of EF-103
[1] with both hands, set EF-103 [1] on the fixing position with
arrow mark.

NOTICE

Make sure that the exit section is open before setting EF-103
to the machine. When you try to set the fusing unit with the
exit guide unit closed, the machine may be damaged.

9

Holding the handles on the front and rear sides [2] of EF-103
[1] with both hands, slide it to the direction of arrow until it
knocks in place.

Return the fixing plate [3] to its original position.