Konica minolta mfp support and requirements – Konica Minolta OpenText RightFax User Manual

Page 7

Advertising
background image

Configuring the OpenText RightFax Native Connector for Konica Minolta MFP

7

Konica Minolta MFP Support and Requirements

For a list of supported Konica Minolta MFP devices, see

http://faxsolutions.opentext.com/konica-minolta-integration.aspx

on the OpenText Web site.

Configuring Connector Settings on the RightFax
Server

To configure the Native Connector for Konica Minolta MFP, use the
EDC Configuration Wizard that is included as part of the RightFax
server installation. To run the EDC Configuration Wizard:

1. On the Start menu of the RightFax server, click All Programs

and then click OpenText. Click RightFax EDC Monitor.

2. If you are running EDC Monitor for the first time, you will be

prompted to initialize EDC. Click Yes. The EDC Configuration
Wizard appears.

If EDC has already been initialized, EDC Monitor will open in its
default Activity view. On the Tools menu, click EDC
Configuration.

3. On the first page of the configuration wizard:

If you are installing the connector for the first time, select

Add/Remove modules and then click Next.

If you want to make changes to an existing connector,

select Modify a module and then click Next.

4. On the Add/Remove Modules page, select the Konica Minolta

MFP check box. If a Module Dependencies dialog box appears,
click OK to continue; the additional modules will be installed
automatically. Click Next.

5. On the Wizard Summary page, verify that the information is

correct and click Next to configure the connector.

6. On the Select Module page, select Konica Minolta MFP in the

list of modules and then click Next.

7. On the Print Notifications? page, select Print Notification if

you want a transmission status message to be automatically
printed on the MFP each time it is used. Click Next.

8. On the Email Notifications? page, select Email Notifications if

you want a transmission status message to be automatically
emailed to the sender for each fax sent. If you select this
option, specify an SMTP server name, the email address from
which notification emails should be sent, and a name that will
appear as the sender of email notifications. Click Next.

9. The FTP Configuration page displays the server name and the

default port 21. You can make any of the following optional
changes:

Change the port number.

Deselect the Use Anonymous checkbox and then enter an

FTP user name and password (see

“Securing

Communication Channels”

on

page 10).

Click Next when done.

10.

On the Wizard Summary page, review the information. Click

Back to make changes, or click Finish if you are done.

When you add this module, the following sites are created in IIS
on the RightFax server:

KonicaNative

KonicaNativeDIB

KonicaNative FTP site

After installation, ensure the the authentication mode is set to
“Anonymous” for all of the above sites.

You may need to start the services if they are not running. If
the services are not running, perform the following steps:

1. On the Start menu of the RightFax server, click All Programs

and then click OpenText. Click RightFax EDC Monitor.

2. On the EDC Monitor Tools menu, click Services.

3. Click Start All Services.

Advertising