Ad-20, Gas electric, Electrical service specifications (per dryer) – American Dryer Corp. AD-20 User Manual

Page 23

Advertising
background image

19

IMPORTANT: Figures shown are for non-reversing models ONLY.

IMPORTANT: The wire size must be properly sized to handle the related current.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or

obligation.

Gas

Electric

AD-20

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

NOTES: A.

B.


C.

When fuses are used they must be dual element, time delay, current limiting, class
RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either
local and/or National Electrical Codes to listed appliance amp draw data.

Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For
others, calculate/verify correct breaker size according to appliance amp draw

rating and type of breaker used.

Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

120

2

10.9

---

15

240

3

6

15

240

3

5.8

---

15

240

3

---

28.5

35

240

3

28.3

---

35

416

4

---

18

25

Advertising