American Dryer Corp. Microprocessor 8.4 Rev 2.2 User Manual

Page 12

Advertising
background image

12

American Dryer Corp.

113604 - 4

When a cycle is running, the control will display DIAGNOSTIC
MODE at the top of the display.
If a fault occurs during Diagnostic Mode, the control will enter into
a fault cool down and the occurring fault will be displayed. The
fault can be cleared by reentering the diagnostic cycle.

3: HELP MENU

The help menu allows the user to view the status of different
parts of the dryer. When a feature is highlighted, the center section
will list that feature and its current status. The items in the help
menu will refer to the current running cycle that was selected in
Diagnostic Mode.
Pressing the HI/UP ARROW key will allow the user to move the
highlighted bar around the help menu screen. For example,
highlighting “S” will show the status of the sail switch.
Pressing the PAUSE/STOP key will return the controls to
Diagnostic Mode.
The table below shows the standard features available and the
symbol they correlate with.

HELP

CODE

CODE DESCRIPTION

81

Lower Exhaust Probe Fault

86

Upper Exhaust Probe Fault

87

Upper Axial Probe Fault

82

Lower Axial Probe Fault

89

Upper Sail Switch Open Fault

88

Upper Sail Switch Closed Fault

84

Lower Sail Switch Open Fault

83

Lower Sail Switch Closed Fault

90

Upper Rotation Sensor Fault

91

Lower Rotation Sensor Fault

92

Gen 2 Card Reader Communication Fault

E1

Top Radiant Sensor fault count

E2

Top Burner Ignitor fault count

E3

Top Exhaust High Limit

E4

Bottom Radiant sensor fault count

E5

Bottom Burner Ignitor fault count

E6

Bottom Exhaust High Limit

E7

Coin 1 Bad Coin count

E8

Coin 2 Bad Coin Count

E9

Upper pocket forward rotation sensor fault count

EA

Upper pocket reverse rotation sensor fault count

EB

Lower pocket forward rotation sensor fault count

EC

Lower pocket reverse rotation sensor fault count

ED

S.A.F.E. DISABLED – Water not connected

If a fault occurs while in Help Mode, the fault will be
displayed as a Help Code or Event Code.
Codes can be cleared by pressing and holding the
PAUSE/STOP key for 3-seconds.
The last item listed in the code menu will identify the
revision of the software that is being used on the control
board.

If the help menu feature “CODE” is selected, the center
section will present “Help Codes” and “Events”. All of the
items in the code menu will automatically scroll up and
continue to scroll until LOW/DOWN ARROW key is
pressed to select a new help menu feature.
All CODES starting with an “H” represent some condition
that could interfere with the proper functioning of the dryer.
There could be up to 3 “H” codes listed within the HELP
MENU.

H1 represents the last failure recorded.

H2 represents the second to last failure recorded.

H3 represents the third to last failure recorded.

Each Help Code will be followed by a two digit code. This
two digit code will reflect a particular issue.

FEATURE

SYMBOL

FEATURE

TEXT

FEATURE

FEATURE

INFORMATION

EXH

EXHAUST

TEMP PROBE

Exhaust

Temperature Probe

(in Deg. F or C)

AXL

AXIAL TEMP PROBE

Axial Thermistor Probe

(in Deg. F or C)

RPM

TUMBLER

ROTATION SPEED

Tumbler Speed in

Revolutions Per Minute

R.P.M.

MIN

TIME REMAINING

Time remaining

in the diag. cycle

0 to 99
(in minutes)

CODE

HELP CODE MENU

Help Menu Code

Help Codes

T1

THERMOSTAT

BURNER 1

Thermostat

(Heat Output Burner 1)

ON - OFF

T2*

THERMOSTAT

BURNER 2

Thermostat

(Heat Output Burner 2)

ON - OFF

H1

HEAT RETURN
BURNER 1

Heat Return Burner 1

ON - OFF

H2*

HEAT RETURN
BURNER 2

Heat Return Burner 2

ON - OFF

C1

HEAT RELAY 1
CONTACTS

Heat relay 1 contacts

OPEN - CLOSED

C2*

HEAT RELAY 2
CONTACTS

Heat relay 2 contacts

OPEN - CLOSED

B

BLOWER

Fan output

ON - OFF

F

FORWARD

Forward drive output

ON - OFF

R

REVERSE

Shows reversing
relay is on

ON - OFF

D

DOOR

Main Door

OPEN - CLOSED

L

LINT

Lint Door

OPEN - CLOSED

P

WATER PRESSURE

H

2

O Input

ON - OFF

S

SAIL SWITCH

Sail Switch

OPEN - CLOSED

V

VAULT SWITCH

Vault Switch

OPEN - CLOSED

W

WATER OUTPUT

S.A.F.E. output

ON - OFF