2.3 Connecting the Thermostat

Refer to the following table for matching the wire labels with the
thermostat terminals.

Note: Do not connect wires identified as C, X or B. Wrap the bare
end of these wires with electrical tape.

n

Loosen the screws of the terminal
block and insert the wires in the
respective terminals.

o

Tighten the screws.

Important: The red jumper wire between
Rh and Rc terminals must be removed in a
5-wire installation.

2.3.1 2-wire Heating

2.3.2 2-wire Cooling

2.3.3 3-wire Heating

2.3.4 3-wire Cooling

2.3.5 4-wire Heating and Cooling

2.3.6 5-wire Heating and Cooling

Note

: Remove the red jumper wire between terminals Rc and Rh.

2.4 Remote Control Input (TH148LE-P only)

The TH148LE-P thermostat has an input to which a CT240 tele-
phone controller (optional) or any other remote control system (e.g.,
home automation) can be connected. When the input receives a
12-VDC signal, the thermostat switches from its current mode to the
unoccupied mode and vice versa when the signal is removed.
The unoccupied mode can be used to re-adjust the temperature to
save energy when you are away for an extended period of time. To
set the unoccupied mode temperature, see section 4.

2.4.1 Connecting to CT240

Connect TH148LE-P terminals UN and UN to
CT240 terminals A and C (no polarity to observe).

2.4.2 Connecting to a Home Automation System

Connect TH148LE-P terminals UN and UN to a
12-VDC circuit as shown.

2.5 Setting JP2 Jumper

The jumper specifies how the fan will operate when it is placed in
automatic mode.

Terminals

Description

Wire labels

Rh

Heating power supply

Rh, R, 4, V

Rc

Cooling power supply

Rc, R

W

Heating signal

W, W1, H

Y

Cooling signal

Y, Y1, M

G

Fan

G, F

Un / Un

Input for a remote control device (TH148LE-P only)

-

Heat relay

Cool relay

Fan relay

Heat relay

Cool relay

Fan relay

HG

Leave the jumper in this position if you
have a gas or fuel oil furnace.

HE

Place the jumper in this position if you
have an electric furnace.

Heat relay

Cool relay

Fan relay

Fan relay

Cool relay

Heat relay

JP2 jumper