Section 61150.052L1-5, Issue 1

4.

FACEPLATE INDICATORS
Table C
shows the status indicators for incoming

power, ringing voltage, and outgoing voltages.

-42.25 VDC to -56.00 VDC,
-48 VDC, nominal
3.0 A

0 Vrms to 120 Vrms
105 Vrms, nominal
0.25 A

+5 VDC

±

5%

4 A, maximum

+12 VDC

±

10%

1 A, maximum

-12 VDC

±

10%

1 A, maximum

-42.25 V to -56.00 V
2 A, maximum

0 to 120 Vrms
105 V, nominal
0.25 A, maximum

DC Voltage

Current

Ringing Voltage

Current

+5 V

+12 V

-12 V

-48 V filtered

20 Hz

Input

Output

Table B. ACT PSU Specifications

Figure 2. Connector Pin Assignments

901 Explorer Boulevard • Huntsville, Alabama • 35806-2807 • (205) 971-8000 • FAX (205) 971-8699

3.

CONNECTIONS

3.1

Figure 2 shows the ACT PSU connector pin

assignments. All inputs and outputs to the ACT PSU are
made through the backplane. No additional backplane
wiring is necessary for normal operation.

Indicator

PWR ON,
20 HZ ON

PWR FAIL

Description

Indicator turns

On whenever incoming

power or ringing voltage is present.

Indicator turns

On whenever one of the

outgoing voltages of the individual PSU has
failed.

Table C. Faceplate Indicators

5.

MAINTENANCE

5.1

The ACT PSU requires no routine maintenance

to operate properly.

The faceplate has two faceplate fuses. If a fuse

blows, a colored pin becomes visible from the front of the
channel bank. To remove a fuse, grasp it and firmly pull
it from the holder. To insert a fuse, push it into the holder
until it firmly seats.

5.2

ADTRAN does not recommend that repairs be

performed in the field. Repair services may be obtained
by returning the defective unit to the ADTRAN Repair
Department (see subsection 6.2).

6.

WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within

five years from the date of shipment, if the product does
not meet its published specifications or if it fails while in
service. For detailed warranty, repair, and return
information, refer to the ADTRAN Equipment Warranty
and Return Policy Procedure.

6.1

Return Material Authorization (RMA) is required

prior to returning equipment to ADTRAN.

6.2

For service, RMA requests, or further information,

contact one of the following numbers.

ADTRAN Customer Service:
RMA

(205) 971-8722

Technical Support

(800) 726-8663

Applications Engineering

(800) 615-1176

Sales

(800) 827-0807

Repair and Return Address:
ADTRAN, Inc.
Customer Service Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

TPSS
TSPV
RSPV
PFAIL

20 Hz FUSED
20 Hz IN

GND
GND
- 12 V
+ 12 V
GND
GND
+ 5 V
+ 5 V
- 48 F
- 48 F
- 48 V
- 48 V
- 48 V IN
- 48 V IN
FRM GND

MAD0
MAD1
MAD2

20 Hz FUSED RET

20 Hz IN RET

GND
GND

- 12 V

+ 12 V

GND
GND

+ 5 V
+ 5 V

- 48 FRT
- 48 FRT

- 48 VRT
- 48 VRT

- 48 IN RT
- 48 IN RT

FRM GND

Advertising