MAINTENANCE

ERROR MESSAGE

AND DESCRIPTION

POSSIBLE SOLUTION

Port CP

Missing

B u t

Check CP slot; reseat CP; change

“Administered:

(Other

t h a n

CP; or

remove

C P f r o m

CPU/Memory) Translated port CP

translations. If CP does not pass

that CPU cannot access.

power-up, replace CP.

Port CP Out Of Service: (Other

If the CP has not been removed

than

CPU/Memory)

Message

and the problem persists, check

occurs when a CP is removed

or replace the port CP.

from a cabinet. Error removed
when the CP passes power-up.

Port CP ROM Checksum Failure:

Try reseating the CP. If this error

The port CP has found that the

happens again, then replace the

checksum on its firmware is bad.

C P .

Port Buffer Full:

(STARLAN

If the reset is not successful,

Interface CP) This error resets the

reseat CP. If the reseat fails,

C P .

replace the CP.

Port Fault: For an auxiliary trunk,

C h e c k

wiring of

external

this message is logged when a

equipment (see Figure 4-7).

ground is expected from external
equipment and is not detected.

Port Queue Full:

(STARLAN

If the reset is not successful,

Interface CP) This error resets the

reseat CP. If the reseat fails,

C P .

replace the CP.

Program

L o g i c Inconsistent:

Reseat CP. If problem persists,

( O t h e r

t h a n

CPU/Memory)

replace it.

Possible hardware problem on
port CP.

RAM Test Failed: CPU/Memory

Check CPU/Memory CP.

CP has failed the RAM test.

4-42