Wiring Connections

The rotator unit must be wired to the
control unit with 4-wire cable. The
gauge of the 4-wire cable to connect the
control unit to the rotator depends upon
the distance between rotator and
controller. The wire for the impulse
sensing may be quite thin - #22 or similar, even for relatively long
distances.


Length

Gauge

Motor

10 m (32')

#18 (1.19 mm)

30

m

(100')

#16

(1.42

mm)

60

m

(200')

#14

(1.75

mm)


Remove cover from the motor body as shown and make connections
as follows:

1 Motor Drive to 1 on controller terminal
2 Motor Drive to 2 on controller terminal
3 Impulse Sense to 3 on controller terminal
4 Impulse Sense to 4 on controller terminal