Alcatel-Lucent OmniSwitch 6400 | Data Sheet

Power supplies and power
consumption

• Supports redundant hot-swappable

power supplies

• AC supplies: 90 V to 220 V AC

• DC supplies: 36 V to 72 V DC

Non-PoE models

• Uses internal main power supplies

and external backup power supplies
directly connected to the rear of
the unit or remotely mounted

• Backup power supplies use a power

shelf to hold one 6400-BP (AC) or
one 6400-BP-D (DC) supply

PoE models

• 360-W (AC) and 510-W (AC) power

supplies only used with PoE models

• Power shelf holds one 510-W AC,

or two 360-W AC power supplies

• Dynamic power for PoE with 360-W

power supply: 240 W

• Dynamic power for PoE with 510-W

power supply: 390 W

Specifications

Indicators

Per-port LEDs

• 10/100/1000: PoE, link/activity

• SFP: link/activity

• Stacking: link/activity

System LEDs

• Switch ID (indicates the stack ID

of the unit in the stack: 1 to 8)

• System (OK) (chassis HW/SW status)

• PWR (primary power supply status)

• PRI (virtual chassis primary)

• BPS (backup power status)

Physical dimensions (WxDxH)

Chassis size (without mounting brackets)

24-port non-PoE and fiber with

internal power supply

• Height: 1.73 in. (4.4 cm)

• Width: 17.32 in. (44.0 cm)

• Depth: 10.63 in. (27.0 cm)

48-port non-PoE with internal power

supply

• Height: 1.73 in. (4.4 cm)

• Width: 17.32 in. (44.0 cm)

• Depth: 13.0 in.(33.0 cm)

24-port PoE without power shelf

• Height: 1.73 in. (4.4 cm)

• Width: 17.32 in. (44.0 cm)

• Depth: 10.63 in. (27.0 cm)

48-port PoE without power shelf

• Height: 1.73 in. (4.4 cm)

• Width: 17.32 in.(44.0 cm)

• Depth: 10.63 in. (27.0 cm)

Total sizes including power supply shelf

for PoE and backup supply

• 17.32 x 17.56 x 1.73 in (44.0 x

44.6 x 4.4 cm) for 10.63 inch chassis

• 17.32 x 19.93 x 1.73 in (44.0 x

50.6 x 4.4 cm) for 13.00 inch chassis

Note: All chassis are 19” (48.2 cm)
wide with mounting brackets installed

Weight

Chassis

Non-PoE with internal supply

• OS6400-24 9.43 lbs (4.28 kg)

• OS6400-48 11.97 lbs (5.43 kg)

• OS6400-U24 9.76 lbs (4.43 kg)

• OS6400-U24D 9.23 lbs (4.189 kg)

PoE without internal power supply

• OS6400-P24 8.97 lb (4.07 kg)

• OS6400-P48 9.92 lb (4.50 kg)

Power supplies

• OS6400-BP 126W AC: 2.45 lb

(1.11 kg)

• OS6400-BP-D 120W DC: 2.09 lb

(0.95 kg)

• OS6400-BP-P 360W AC: 3.22 lb

(1.46 kg)

• OS6400-BP-PH 510W AC: 5.71 lb

(2.59 kg)

• Power shelf: 1.26 lb (0.57 kg)

EMC

• FCC CRF Title 47 Subpart B (Class

A limits. Note: Class A with UTP
cables)

• VCCI (Class A limits. Note: Class

A with UTP cables)

• AS/NZS 3548 (Class A limits. Note:

Class A with UTP cables)

• CE marking for European countries

(Class A Note: Class A with UTP
cables)

• EN 55022: 1995 (Emission Standard)

• EN 61000-3-3: 1995

• EN 61000-3-2: 2000

• EN 55024: 1998 (Immunity

Standards)

• EN 61000-4-2: 1995+A1: 1998

• EN 61000-4-3: 1996+A1: 1998

• EN 61000-4-4: 1995

• EN 61000-4-5: 1995

• EN 61000-4-6: 1996

• EN 61000-4-8: 1994

• EN 61000-4-11: 1994

• IEEE 802.3: Hi-Pot Test (2250

VDC on all Ethernet ports)

Safety agency certifications

• US UL 60950

• IEC 60950-1:2001; all national

deviations

• EN 60950-1: 2001; all deviations

• CAN/CSA-C22.2 No. 60950-1-03

• NOM-019 SCFI, Mexico

• AS/NZ TS-001 and 60950:2000,

Australia

• UL-AR, Argentina

• UL-GS Mark, Germany

• EN 60825-1 Laser, EN60825-2 Laser

• CDRH Laser

• China CCC

Environmental requirements

Operating temperature:

• 32° to 113°F (0° to 45°C)

Storage temperature:

• -40° to 167°F (-40° to 75°C)

Humidity (operating and storage):

• 5% to 95% non-condensing

IEEE standards

• IEEE 802.1D (STP)

• IEEE 802.1p (CoS)

• IEEE 802.1Q (VLANs)

• IEEE 802.1ad Q-in-Q (VLAN stacking)

• IEEE 802.1ag (Connectivity Fault

Management)

• IEEE 802.1s (MSTP)

• IEEE 802.1w (RSTP)

• IEEE 802.1X (Port Based Network

Access Protocol)

• IEEE 802.3i (10BaseT)

• IEEE 802.3u (Fast Ethernet)

• IEEE 802.3x (Flow Control)

• IEEE 802.3z (Gigabit Ethernet)

• IEEE 802.3ab (1000BaseT)

• IEEE 802.3ac (VLAN Tagging)

• IEEE 802.3ad (Link Aggregation)

• IEEE 802.3af (Power-over-Ethernet)

IETF standards

IPV4

• RFC 2003 IP/IP tunneling

• RFC 2784 GRE tunneling

RIP

• RFC 1058 RIP v1

• RFC 1722/1723/2453/1724 RIP

v2 & MIB

• RFC 1812/2644 IPv4 Router

Requirement

• RFC 2080 RIPng

IP Multicast

• RFC 1112 IGMP v1

• RFC 2236/2933 IGMP v2 & MIB

• RFC 2365 Multicast

• RFC 3376 IGMPv3

IPV6

• RFC 1886 DNS for IPv6

• RFC 2292/2373/2374/2460/2462 IPv6

• RFC 2461 NDP

• RFC 2463/2466 ICMP v6 & MIB

• RFC 2452/2454 IPv6 TCP/UDP MIB

• RFC 2464/2553/2893/3493/3513 IPv6

• RFC 3056 IPv6 Tunneling

• RFC 3542/3587 IPv6

Manageability

• RFC 854/855 Telnet & Telnet options

• RFC 1155/2578-2580 SMI v1 &

SMI v2

• RFC 1157/2271 SNMP

• RFC 1212/2737 MIB & MIB-II

• RFC 1213/2011-2013 SNMP v2 MIB

• RFC 1215 Convention for SNMP Traps

• RFC 1573/2233/2863 Private

Interface MIB

• RFC 1643/2665 Ethernet MIB

• RFC 1901-1908/3416-3418 SNMP v2c

• RFC 2096 IP MIB

• RFC 2570-2576/3411-3415 SNMP

v3

• RFC 2616 /2854 HTTP & HTML

• RFC 2667 IP Tunneling MIB

• RFC 2668/3636 IEEE 802.3 MAU MIB

• RFC 2674 VLAN MIB

• RFC 4251 Secure Shell Protocol

architecture

• RFC 4252 The Secure Shell (SSH)

Authentication Protocol

Security

• RFC 959/2640 FTP

• RFC 1321 MD5

• RFC 2104 HMAC Message

Authentication

• RFC 2138/2865/2868/3575/2618

RADIUS Authentication & Client MIB

• RFC 2139/2866/2867/2620

RADIUS Accounting & Client MIB

• RFC 2228 step

• RFC 2284 PPP EAP

• RFC 2869/2869bis RADIUS

Extension

Quality of Service

• RFC 896 Congestion control

• RFC 1122 Internet hosts

• RFC 2474/2475/2597/3168/3246

DiffServ

• RFC 3635 Pause control

* Contact for availability.