Straight-through wiring, Table b-1, 10/100base-tx mdi and mdi-x port pinouts – Accton Technology ES4524M-POE User Manual

Page 46: Figure b-2

Advertising
background image

Cables

B-2

B

Straight-Through Wiring

If the twisted-pair cable is to join two ports and only one of the ports has an internal
crossover (MDI-X), the two pairs of wires must be straight-through. (When
auto-negotiation is enabled for any RJ-45 port on this switch, you can use either
straight-through or crossover cable to connect to any device type.)

You must connect all four wire pairs as shown in the following diagram to support
Gigabit Ethernet connections.

Figure B-2 Straight-through Wiring

Table B-1 10/100BASE-TX MDI and MDI-X Port Pinouts

Pin

MDI Signal Name

MDI-X Signal Name

1

Receive Data plus (RD+)

and GND (Positive V

port

)

Transmit Data plus (TD+)

and -48V feeding power (Negative V

port

)

2

Receive Data minus (RD-) and

and GND (Positive V

port

)

Transmit Data minus (TD-)

and -48V feeding power (Negative V

port

)

3

Transmit Data plus (TD+)

and -48V feeding power (Negative V

port

)

Receive Data plus (RD+)

and GND (Positive V

port

)

6

Transmit Data minus (TD-)

and -48V feeding power (Negative V

port

)

Receive Data minus (RD-)

and GND (Positive V

port

)

4, 5, 7, 8 not used

not used

Note: The “+” and “-” signs represent the polarity of the wires that make up each wire pair.

White/Orange Stripe

Orange

White/Green Stripe

Green

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

EIA/TIA 568B RJ-45 Wiring Standard

10/100BASE-TX Straight-through Cable

End A

End B

Blue

White/Blue Stripe

Brown

White/Brown Stripe

Advertising