Amana UXG7480V User Manual

Wall-mount canopy grill vent hood

Advertising
background image

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

INSTALLATION DIMENSIONS

LOCATION REQUIREMENTS

UXG7360V
UXG7480V

Electrical: 120-volt, 60-Hz, AC-only, 15-amp fused electrical circuit
is required.

Wall-Mount Canopy Grill Vent Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10153187

02-20-09

X

A

18"

(45.7 cm)

12"

(30.5 cm)

4"

(10.2 cm)

24"

(61.0 cm)

30" (76.2 cm)
36" (91.4 cm)
48" (121.9 cm)

Vented installations

Canopy grill vent hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.

Venting methods

This canopy grill vent hood is factory set for venting through the roof
or through the wall. A 10" (25.4 cm) round vent system is needed for
installation (not included). The hood exhaust opening is 10" (25.4 cm)
round.

NOTE: Flexible vent is not recommended. Flexible vent creates back
pressure and air turbulence that greatly reduce performance. Vent
system can terminate either through the roof or through the wall. To
vent through a wall, a 90° elbow is needed.

Rear discharge

A 90° elbow may be installed immediately above the hood.

*NOTE: The grill vent hood
duct cover is designed to add
12" (30.5 cm) to meet the
ceiling or soffit height.
Depending on your model,
order:

Part Number W10153151 for
30" (76.2 cm) models,
Part Number W10153152 for
36" (91.4 cm) models,
Part Number W10153153 for
48" (121.9 cm).

IMPORTANT:

Minimum distance “X”:
30" (76.2 cm)

Suggested maximum
distance “X”: 36" (91.4 cm)

M

Roof Venting

Wall Venting

A. Optional decorative duct cover
B. 10" (25.4 cm) round vent

C. Roof cap
D. 10" (25.4 cm) round vent

transition

A. Optional decorative duct cover
B. 10" (25.4 cm) round vent and

elbow

C. Wall cap
D. 10" (25.4 cm) round vent

transition

A

A

B

B

C

C

D

D

Calculating Vent System Length

To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.

Maximum equivalent vent length is 35 ft (10.7 m).

Vent Piece

10" (25.4 cm) Round

45° elbow

2.5 ft
(0.8 m)

90° elbow

5.0 ft
(1.5 m)

1 - 90° elbow

= 5.0

M

Example vent system

The following example falls within the maximum recommended
vent length of 35 ft (10.7 m).

R

1 - 90° elbow

= 5.0 ft (1.5 m)

1 - wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

Length of system

= 13.0 ft (3.9 m)

90 elbow

6 ft (1.8 m)

2 ft

(0.6 m)

Wall cap

X

Advertising