Problem

Possible cause

Solution

Water flows on the

ground.

The melting water outlet does

not flow in the evaporative tray

above the compressor.

Attach the melting water outlet

to the evaporative tray.

The temperature in the

appliance is too low.

The temperature regulator is not

set correctly.

Set a higher temperature.

The temperature in the

appliance is too high.

The temperature regulator is not

set correctly.

Set a lower temperature.

The door is not closed correctly.

Refer to "Closing the door".

The product temperature is too

high.

Let the product temperature de-

crease to room temperature be-

fore storage.

Many products are stored at the

same time.

Store less products at the same

time.

The temperature in the re-

frigerator is too high.

There is no cold air circulation in

the appliance.

Make sure that there is cold air

circulation in the appliance.

The temperature in the

freezer is too high.

Products are too near to each

other.

Store products so that there is

cold air circulation.

There is too much frost.

Food is not wrapped correctly.

Wrap the food correctly.

The door is not closed correctly.

Refer to "Closing the door".

The temperature regulator is not

set correctly.

Set a higher temperature.

DEMO appears on the dis-

play

The appliance is in demonstra-

tion mode. (dEMo)

Keep the OK button pressed for

approximately 10 second until a

long sound of buzzer is heard and

the display shuts off for a short

time; the appliance starts working

regularly

Warning signal

The warning signals of the control and signalling system of the appliance are displayed on

the Visual Display.

The system will give out a signal if:
• An error has occurred in the operation of

the appliance. In case the electronic system

of the appliance cannot identify the real

temperature a sign will appear on the tem-

perature display.

• Until the staff of the customer service arrive

at the spot and solve the problem, the appli-

ance will continue operating with the help

of a spare program.

16