Installation

4

AXR-RF RF Receiver

Wiring Guidelines

The AXR-RF requires regulated ±12 VDC power to operate properly. The Central Controller

supplies power via the AXlink cable. The maximum wiring distance between the Central Controller

and AXR-RF is determined by power consumption, supplied voltage, and the wire gauge used for

the cable. The table below lists wire sizes and maximum lengths allowable between the AXR-RF

and Central Controller. The maximum wiring lengths for using AXlink power are based on a

minimum of ±13.5 VDC (no load voltage), available at the Central Controller's power supply.

If you install the AXR-RF farther away from the Central Controller than recommended in the

Wiring Specifications table, an auxiliary ±12 VDC power supply is required for operation.

Wiring the AXR-RF

The AXR-RF uses a rear 4-pin AXlink connector for power and data. Power can be supplied by

Central Controller's AXlink cable, or with an optional auxiliary ±12 VDC power supply.

Using the AXlink 4-pin connector for data and power

Connect the Central Controller's AXlink connector to the AXlink connector (male) on the rear

panel of the AXR-RF for data and ±12 VDC power.

Using the AXlink 4-pin connector with an external ±12 VDC power supply

Use an auxiliary ±12 VDC power supply when the distance between the Central Controller and

AXR-RF exceeds the limits described in the Wiring Specifications table. To use an external power

supply, connect the Central Controller's AXlink connector to the AXlink connector on the rear of

the AXR-RF, as shown in FIG. 2.

Wiring Specifications

Wire size

Maximum wiring length

18 AWG

1805.7 feet (550.37 m)

20 AWG

1142.4 feet (348.20 m)

22 AWG

712.2 feet (217.07 m)

24 AWG

448.9 feet (136.82 m)

FIG. 2 Auxiliary power supply connection

PWR (+)

GND (-)

+12 VDC power supply (from PSN6.5)

AXR-RF

Central Controller

Do not connect the wire from the PWR (+) terminal on the Central Controller to the
PWR (+) terminal on the AXR-RF when you connect an external power supply.
Do not connect power to the AXR-RF until the wiring is complete.