American Standard CADET 2568 User Manual

Page 4

Advertising
background image

7 3 0 1 2 7 0 - 1 0 0 R e v . D

12

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE CORRECTIVE ACTION

Does not flush

a. Water supply valve closed.

a. Open valve and allow water to fill tank.

b. Supply line blocked.

b. Shut off water supply, disconnect supply line, and inspect

all gaskets and washers. Reassemble. Also, see Fluidmaster

maintenance (see step 12).

c. Flush valve chain too loose or disconnected.

c. Readjust chain length as required.

d. Sand or debris lodged in water control.

d. Shut off water supply. Remove cap and clean per Step 12.

Poor or sluggish flush

a. Bowl water level too low.

a. Check that refill tube is connected to water control and

inserted into tank overflow without being kinked or damaged.

b. Supply valve partly closed.

b. Open supply valve fully. Be sure that proper supply tube size is used.

c. Partially clogged trapway and/or drain pipe and/or vent.

c. Remove obstruction. Consult a plumber if necessary.

d. Supply pressure too low.

d. Normal supply pressure must be at least 20 psi.

Toilet leaks

a. Poor supply line connection.

a. Review Step 8 of installation procedure.

b. Poor bowl to tank/floor connection.

b. Review Step 4 through 6 of installation procedure.

Toilet does not shut off

a. Flush valve chain too tight, holding flush valve open.

a. Readjust chain length as needed. Review step 9.

b. Flush valve seat and/or flapper worn or deformed.

b. Replace flapper/flush valve assembly, as needed.

c. Sand or debris lodged in water control.

c. Shut off water supply. Remove cap and clean per Step 12.

- 4 -

In the United States:

American Standard Brands

P.O. Box 6820

Piscataway, New Jersey 08855

Attention: Director of Consumer Affairs

For residents of the United States, warranty

information may also be obtained by calling

the following toll free number: (800) 442-1902

www.americanstandard-us.com

In Canada:

AS Canada ULC

2480 Stanfield Rd.

Mississauga, Ontario

Canada L4Y 1S2

Toll Free: (800) 387-0369

www.americanstandard.ca

In Mexico:

Customer Service Manager

AS Maquila, S.A. de C.V.

Via Morelos #330

Col. Santa Clara

Ecatepec 55540 Edo. Mexico

www.americanstandard.com.mx

• Make sure water supply is
off. Remove valve TOP by
lifting arm and rotating top
and arm 1/8 turn
counterclockwise, pressing
down slightly on cap.

IMPORTANT: Always
clear sand and rust from
system.

• While holding a
container over the
uncapped VALVE to
prevent splashing, turn
water supply on and off
a few times. Leave
water supply off.

Replace TOP by engaging
lugs and rotating 1/8 turn
clockwise. MAKE
CERTAIN TIP IS TURNED
TO THE LOCKED
POSITION. VALVE MAY
NOT TURN ON IF TOP IS
NOT FULLY TURNED TO
THE LOCKED POSITION.

For troubleshooting information please contact:

TROUBLESHOOTING

IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK
SLOWLY,
repeat Step 12.

IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF
NON-USE,
it is a signal you are wasting water because:

• The end of the refill tube is inserted into overflow pipe, below
water level in tank. Attach refill tube to overflow pipe using "S"
clip provided.

• The flush valve is leaking because it's worn, dirty or misaligned
with tank ball or flapper (replace with a new flapper).

IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL
OF TANK WATER IS SLOW after valve has been in use for
some time,
Fluidmaster Model 242 Replacement Seal may be
needed.

Go to our website at www.fluidmaster.com for more
solutions to toilet problems.

© 2001 Fluidmaster, Inc.
® Registered trademark of Fluidmaster, Inc.

Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster
shall not be responsible or liable for any damages caused by products used with Fluidmaster valves
that were not manufactured by Fluidmaster, Inc.

30800 Rancho Viejo Road

San Juan Capistrano, CA 92675

(949) 728-2000 (800) 631-2011

www.fluidmaster.com