Troubleshooting, 2 cleaning the spray arms, 3 external cleaning – AEG F55602VI0P User Manual

Page 30: 4 internal cleaning

Advertising
background image

6.

Make sure that the filter (B) is cor-
rectly positioned under the 2 guides
(C).

7.

Assemble the filter (A) and put it
back in filter (B). Turn it clockwise
until it locks.

An incorrect position of the filters
can cause bad washing results
and damage to the appliance.

9.2 Cleaning the spray arms

Do not remove the spray arms.
If the holes in the spray arms are clog-
ged, remove remaining parts of soil with
a thin pointed object.

9.3 External cleaning

Clean the appliance with a moist soft
cloth.
Only use neutral detergents. Do not use
abrasive products, abrasive cleaning
pads or solvents.

9.4 Internal cleaning

If you regularly use short duration pro-
grammes, these can leave deposits of
grease and limescale inside the appli-
ance.
To prevent this, we recommend to run
long duration programmes at least 2
times per month.

10. TROUBLESHOOTING

The appliance does not start or it stops
during operation.
Before you contact the Service, refer to
the information that follows for a solu-
tion to the problem.
With some problems, the display
shows an alarm code:

- The appliance does not fill with

water.

- The appliance does not drain

the water.

- The anti-flood device is on.

WARNING!
Deactivate the appliance before
you do the checks.

Problem

Possible solution

You cannot activate the appli-
ance.

Make sure that the mains plug is connected
to the mains socket.

Make sure that there is not a damaged fuse
in the fuse box.

The programme does not start.

Make sure that the appliance door is closed.

If the delay start is set, cancel the setting or
wait for the end of the countdown.

The appliance does not fill with
water.

Make sure that the water tap is open.

30 www.aeg.com