Broan NuTone 336 User Manual

Read and save these instructions model 336, Exterior mounted blower, Warning

Advertising
background image

READ AND SAVE THESE INSTRUCTIONS

MODEL 336

EXTERIOR MOUNTED BLOWER

FOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODS
FOR USE WITH "BEST BY BROAN" K-210A OR K-260A SERIES RANGE HOODS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.

Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or phone number listed in the warranty.

2.

Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.

3.

Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.

4.

Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.

CAUTION

1. For general ventilating use only. Do not use to exhaust

hazardous or explosive material and vapors.

2. To avoid motor bearing damage and noisy and/or unbal-

anced impellers, keep drywall spray, construction dust, etc.
off power unit.

3. Please read specification label on product for further informa-

tion and requirements.

4. Electrical circuit, including speed control, (if used), must be

rated 6 AMPS minimum.

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

336

120

3.8

1500

10" DIA.

SPECIFICATIONS

INSTALLER: Leave This Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

MODEL 336

EXTERIOR BLOWER

WALL HOOD

CANOPY

(island canopy

available)

10" ROUND

DUCT

SOFFIT

ROUGH-IN

PLATE

24" or 27"

18"

DUCT

OPENING

COVER PLATE

MODEL

336

EXTERIOR

BLOWER

WALL HOOD

CANOPY

(island canopy

available)

10" ROUND DUCT

SOFFIT

ROUGH-IN

PLATE

24" or 27"

18"

10" ROUND ELBOW

DUCT

OPENING

COVER PLATE

TYPICAL ROOF MOUNTED INSTALLATION

(Vertical discharge)

TYPICAL WALL MOUNTED INSTALLATION

(Vertical discharge - elbow to horizontal)

WARNING

5. When cutting or drilling into wall, or ceiling, do not damage

electrical wiring or other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.

MODEL 335
EXTERIOR
BLOWER

WALL HOOD

CANOPY

(island canopy

available)

10" ROUND DUCT

SOFFIT

ROUGH-IN

PLATE

24" or 27"

18"

DUCT

OPENING

COVER

PLATE

PLAN THE INSTALLATION

1.

Locate the blower so the length of the duct run and number
of elbows needed are kept to a minimum.

ALL INSTALLATIONS

TYPICAL WALL MOUNTED INSTALLATION

(Horizontal discharge)

2.

Where possible, blower should be centered between wall
studs or roof rafters.

3.

Avoid pipes, wires, or other ductwork that may be running
through the wall.

NOTE: Horizontal discharge requires relocation of the duct
opening cover plate. See hood manual for instructions.

MODEL
336
EXTERIOR
BLOWER