New Buck Corporation 94NC User Manual

Page 17

Advertising
background image

B. Wall Exit Into Metal Tee-Box

1. Mark plumb line on wall directly behind center of heater. (See Figure 11).

NOTE: When using 24# ga. minimum blue or black steel pipe, maintain 18" between

pipe and ceiling.

NOTE: Floor protector must be under horizontal pipe exit (See Figure 13. Page 19).

2. Place vertical portion of heater pipe and elbow in position and project a point onto

plumb line level with center of elbow.

Figure 11

ATTIC

CEILING

"TEE" BOX ASSEM.

CENTER LINE
OF ELBOW

MARK PLUMB LINE

WALL

WALL PASS-THROUGH CONNECTOR

18" MIN.

TEE BOX ASSEM.

CLEAN OUT ACCESS

FLOOR PROTECTOR

3 SHEET METAL SCREWS OR RIVETS

CEILING

ROOF

Figure 5

COLLAR

3 SHEET METAL SCREWS

Figure 10

COLLAR

3 SHEET METAL SCREWS

Page 15

Advertising