DPSBSS

Attach one end of the 10" S/S flex line (22) to the
end of the grill’s gas valve.

Attach the other end of the S/S flex line to the
brass “tee” (20). F

IGURE

14.

N

ATURAL

G

AS

C

ONNECTION

The grill’s natural gas supply line valve installed
by your gas company must be turned to OFF.

I

MPORTANT

: T

HE

GAS

SUPPLY

LINE

MUST

HAVE

A

SHUTOFF

VALVE

INSIDE

THE

WALL

. C

ONTACT

YOUR

LOCAL

GAS

COMPANY

FOR

DIRECTIONS

.

Disconnect the copper gas supply line from the
gas valve located under the grill’s control panel.
F

IGURE

13.

Attach one end of the 34" S/S flex line (23) to the
end of the side burner valve (6).

Attach the remaining end of the S/S flex line to
the end of the “tee” (20) connector. F

IGURE

15.

F

IGURE

13

Grill Gas Valve

Gas Supply Line

Attach the copper gas supply line to the brass
“tee” (20). Use two adjustable wrenches to tighten
the joint. F

IGURE

16.

“Tee” (20)

Connection Requirements

Installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1. In Canada, installation shall
be in accordance with CAN/CGA-B149.2 Propane
Installation Code, or CAN/CGA-B149.1 Natural
Gas Installation Code, and local codes where
applicable. Contact your local gas company for
code regulations, recommended procedures, and
the installation of your grill’s gas supply line.

Broilmaster

®

gas grills and side burners are not

equipped with pressure regulators. Your gas grill
operates at a manifold pressure of seven (7")
inches water column.

Connect cart mounted natural gas grills to a pre-
installed gas supply line using the twelve (12') foot
flexible hose and quick disconnect kit supplied or
specified by the manufacturer.

C

AUTION

: T

HE

GRILL

AND

ITS

INDIVIDUAL

SHUTOFF

VALVE

MUST

BE

DISCONNECTED

FROM

THE

GAS

SUPPLY

PIPING

SYSTEM

DURING

ANY

SYSTEM

PRESSURE

TESTING

AT

TEST

PRESSURES

IN

EXCESS

OF

1/2

PSIG.

C

AUTION

: T

HE

GRILL

MUST

BE

ISOLATED

FROM

THE

GAS

SUPPLY

PIPING

SYSTEM

BY

CLOSING

ITS

INDIVIDUAL

MANUAL

SHUTOFF

VALVE

DURING

ANY

PRESSURE

TESTING

OF

THE

GAS

SUPPLY

PIPING

SYSTEM

AT

TEST

PRESSURES

EQUAL

TO

OR

LESS

THAN

1/2 PSIG.

Connection Instructions

F

IGURE

16

“Tee” (20)

Gas Supply Line

F

IGURE

14

Grill Gas Valve

7" S/S flex line (22)

F

IGURE

15

34" S/S flex line (23)

20