Install the ductwork, Install mounting brackets – Best K273 User Manual

Page 6

Advertising
background image

- 6 -

INSTALL THE DUCTWORK

NOTE: To reduce the risk of fire, use only

metal ductwork.

1. Decide where the ductwork will run

between the hood and the outside.

2. A straight, short duct run will allow the hood

to perform most efficiently.

3. Long duct runs, elbows, and transitions will

reduce the performance of the hood. Use

as few of them as possible. Larger ducting

may be required for best performance with

longer duct runs.

4. Install a roof or wall cap. Connect round

metal ductwork to cap and work back to-

wards hood location. Use duct tape to seal

the joints between ductwork sections.

INSTALL MOUNTING
BRACKETS

1. Construct wood wall framing that is flush

with interior surface of wall studs.Make

sure:
a) the framing is centered over installation

location.

b) the height of the framing will allow the

mounting brackets to be secured to

the framing within the dimensions

shown.

2. After wall surface is finished, secure mount-

ing brackets to framing using dimensions

shown.

ROOF CAP

ROUND

DUCT

WALL

CAP

ROUND

ELBOW

HOOD

DECORATIVE

FLUE

24” TO 30” ABOVE

COOKING SURFACE

FRAMING BEHIND DRYWALL

29-9/16” to 35-9/16”

above cooktop

29-9/16" = bottom of hood 24"above cooktop
35-9/16"= bottom of hood 30" above cooktop

10-13/16”

6”

ADAPTER

Advertising