4 of 4, Tech specs – Black Box 232<->488 Converter IC026A-R3 User Manual

Page 4

Advertising
background image

4 of 4

6/14/07
#10470

724-746-5500

blackbox.com

Item

Code

To link an RS-232 device to a 488 bus, order…

232

↔488 Interface Converter

IC026A-R3

You may also need…

IEEE 488 Cable (with Molded Connectors)

6.6-ft. (2-m)

EXN02M

13.1-ft. (4-m)

EXN04M

Individually Shielded Low-Capacitance Cables,

Extra Distance, PVC, 4-Conductor

ERN04A

TECH SPECS

General:
Certification — FCC, CE
Data Buffer — 32 KB, dynamically allocated
Data Format — 7 or 8 data bits, 1 or 2 stop bits; parity odd, even, mark,

space, or disabled

User Controls — Power switch (external), IEEE and Serial parameter

switches (internal); Jumper selection of RS-232 or RS-422 operation
(internal)

Interface — IEEE 488; RS-232/RS-422
Indicators — (5) LEDs: Talk, Listen, Send, Receive, Power
Environment — 32 to 122°F (0 to 50°C); Up to 70% to 95°F (35°C) relative

humidity; Linearly derate 3% relative humidity/degrees C from 95 to
122°F (35 to 50°C)

Power — Input: 100–240 VAC, autosensing, 50–60 Hz, 0.5 A maximum;

Output: 9 VDC, 15 W maximum, 1.7 A

Size — 2.7"H x 5.4"W x 7.5"D (6.9 x 13.7 x 19.1 cm)
Weight — 2.5 lb. (1.1 kg);

Power supply: 0.9 lb. (0.4 kg)

IEEE 488 Interface:
Implementation — C1, C2, C3, C4, and C28 controller subsets; Serial to IEEE:

SH1, AH1, T6, TE0, L4, LE0, SR1, RL0, PP0, DC1, DT0, E1

Terminators — Selectable CR, LF, LF-CR, and CR-LF with EOI
Connectors — Standard IEEE 488 connector with metric studs

Serial Interface:
Character Set — Asynchronous bit serial
Data Format — Selectable 7 or 8 data bits; 1 or 2 stop bits; odd, even,

mark, space, and no parity on transmit

Duplex — Full with Echo/No Echo
EIA RS-232C — AB, BA, BB, CA, CB
EIA RS-422A — Balanced voltage on TxD and RxD
Input Voltage — ±3 volts minimum; 15 volts maximum
Output Voltage — ±5 volts minimum (RS-232C); 5 volts typical (RS-422A)
Serial Control — Selectable CTS/RTS or X-ON/X-OFF
Speed — Selectable 110, 300, 600, 1200, 1800, 2400, 3600, 4800, 7200,

9600, 19,200, and 57,600 bps

Terminators — Selectable CR, LF, LF-CR, and CR-LF
Connectors — DB25 male, DCE configured

The Interface Clear (IFC) signal is used by the System

Controller in order to initialize all device interfaces to a
known state.

The Remote Enable (REN) signal is used by the System

Controller. REN enables a device to go into remote mode
when addressed to listen. When in remote mode, a device will
ignore its local front-panel controls.

The Service Request (SRQ) line is like an interrupt: it may

be asserted by any device to request the Controller to take
some action. The Controller must determine which device
is asserting SRQ by conducting a serial poll. The requesting
device releases SRQ when it’s polled.

Recognize any of these situations?

• You wait more than 30 minutes to get through

to a vendor’s tech support.

• The so-called “tech” can’t help you or gives you

the wrong answer.

• You don’t have a purchase order number and the

tech refuses to help you.

• It’s 9 p. m. and you need help, but your vendor’s

tech support line is closed.

According to a survey by Data Communications

magazine, 90% of network managers surveyed say
that getting the technical support they need is extremely
important when choosing a vendor. But even though
network managers pay anywhere from 10 to 20% of their
overall purchase price for a basic service and support
contract, the technical support and service they receive
falls far short of their expectations—and certainly isn’t
worth what they paid.

At Black Box, we guarantee the best value and the

best support. You can even consult our Technical Support
Experts before you buy if you need help selecting just
the right component for your application.

Don’t waste time and money— call Black Box today.

Why Buy From Black Box?
Exceptional Value. Exceptional
Tech Support. Period.

Advertising