Control features, Automatic defrost cycle features – Bryant HRVBBSVA User Manual

Page 4

Advertising
background image

4

Control

Description

Fan Speed

Control

Dehumidistat

Control

Continuous

Mode

Intermittent

Mode

OneTouch

Yes

No

Yes

Yes

Basic

Yes

No

Yes

No

Standard

Yes

Yes

Yes

Yes

Control Features

Basic Control:
Allows the user to manually set fan speed to low or high as
required to maximize comfort.

Standard Control:
Offers automatic dehumidistat control and the option to select

continuous or intermittent fan operation. Setting the wall control
to low will activate the continuous mode.

OneTouch Control:
Allows control of ventilator with the touch of a button. This

control will operate as a main wall control. The OneTouch will
operate the unit in Intermittent Mode (20 minutes per hour),

continuous low speed, continuous high speed, and off.

Automatic Defrost Cycle Features

All models offer a non--electric defrost cycle feature which

prevents frost and ice buildup within the heat recovery core.
When the outside air temperature falls below 23_F (--5_C) it is

electronically sensed and the dampers close the outside air ports.

This allows warm indoor air to recirculate within the heat
recovery core. The frequency of this cycle increases as the outside

air temperature decreases.

Model

25_F TO 55_F

(---5_C TO ---15_C)

4_F TO ---17_F

(---15.6_C TO ---27.3_C)

BELOW ---18_F

(---27.8_C)

Model

DEFROST*

EXCHANGE{

DEFROST*

EXCHANGE{

DEFROST*

EXCHANGE{

HRVBBLHA

6 Minutes

60 Minutes

6 Minutes

32 Minutes

6 Minutes

20 Minutes

HRVBBSHA

6 Minutes

60 Minutes

6 Minutes

32 Minutes

6 Minutes

20 Minutes

HRVBBSVA

6 Minutes

60 Minutes

6 Minutes

32 Minutes

6 Minutes

20 Minutes

* All defrost times are in the standard mode (as shipped)
{

Time between defrost when within specified temperature range

HR

V

Advertising
This manual is related to the following products: