Main specifications (electronic flash a11) – Olympus XA User Manual

Page 23

Advertising
background image

MAIN SPECIFICATIONS (ELECTRONIC FLASH A11)

Unit type: Automatic electronic flash unit exclusively

for use with Olympus X A and XA2.

Guide number: 10 (ASA 100, meters) or 33 (ASA

100, feet).

Applicable ASA film speeds: ASA 100 and 400.

Flash modes: Normal auto (XA, X A 2 ) and manual

mode ( X A only) with switch lever.

F stop for auto flash: F4

Angle of coverage: Picture area of 35mm focal-length

lens. ( X A and X A 2 utilize 35mm Zuiko lens.)

Number of flashes: Approx. 150 with A A 'penlight'

alkaline battery.

Recycling time: Approx. 7 sec with AA alkaline bat-

tery.

Max. working distance: 2.5m (8.2 ft.) at ASA 100,

5m (16.4 ft.) at ASA 400.

Connection to camera: Fitted onto left-hand edge of

X A ( X A 2 ) .

Power switch: The flash unit is activated by setting

camera's lever to flash symbol, popping up the
charge lamp and initiating electrical charge. The
flash unit turns off when the charge lamp is

pressed down.

Power source: One 1.5V AA 'penlight' battery (in-

cluding Ni-Cd battery).

Dimensions: 60 ( H ) x 36 ( W ) * x 33 (D) mm (2.4" x

1.4" x 1.3").

* Measured from interface.

Weight: 65 grams or 2.3 oz. (less battery).

22

Advertising