ULTRA-CURVE PRO DSP8024

ULTRA-CURVE PRO is switched off.

If you decide to replace the battery yourself please note that you will invalidate your warranty.

+

Disconnect the ULTRA-CURVE PRO from mains before opening the enclosure.

+

Warning: Danger of explosion when battery is placed incorrectly! Replace only with the same
type (see technical specifications). When replacing the battery, the correct polarity should be
observed.

+

Empty batteries are toxic waste and must be disposed of properly.

7.3 MIDI implementation

Function Transmitted

Recognized

Remarks

Basic

Default

X

1 - 16

memorized

Channel

Changed X

1

-

16

-16

Default

X

1,2,3,4

Mode

Messages

X

X

Altered

X

X

Note

X

X

Number

True Voice

X

X

Velocity

Note ON

X

X

Note OFF

X

X

After

Key’s

X

X

Touch

Ch’s

X

X

Pitch Bender

X

X

Control

offset of the first

Change

O

O

controller adjustable

(refer to next table)

Progr.

Change

True #

System Exclusive

O

O

System

Song Pos

X

X

Song Sel

X

X

Common

Tune X

X

System

Clock X

X

Real Time

Commands

X

X

Aux

Local ON/OFF

X

X

All notes OFF

X

X

Messages

Active Sense

X

X

Reset

X

X

Notes

X

X

O = YES

X = NO

Mode 2: OMNI ON, MONO

Mode 3: OMNI OFF, POLY

Mode 4: OMNI OFF, MONO

1 - 100

0 - 99

0 - 99

Mode 1: OMNI ON, POLY

Tab. 7.1: MIDI implementation