Controls—thermostats and zoning, Installation, Manufactured mobile home standards tube routing – Bryant Direct-Vent Downflow Condensing Gas for Manufactured Housing 351DAS User Manual

Page 3

Advertising
background image

—3—

A99001e

CONTROLS—THERMOSTATS AND ZONING

THERMOSTAT—NON-PROGRAMMABLE

For Use with 1-Speed Air Conditioner—TSTATBBNAC01-B

For Use with 2-Speed Air Conditioner—TSTATBBN2S01-B

For Use with 2-Speed Heat Pump—TSTATBBN2S01-B

THERMOSTAT—PROGRAMMABLE

For Use with 1-Speed Air Conditioner—TSTATBBPAC01-B

For Use with 2-Speed Air Conditioner—TSTATBBP2S01-B

For Use with 1-Speed Heat Pump—TSTATBBPDF01-B

For Use with 2-Speed Heat Pump—TSTATBBP2S01-B or TSTATBBPDF01-B

THERMIDISTAT—PROGRAMMABLE THERMOSTAT

with Humidity Control

TSTATBBPRH01-B

INSTALLATION

This forced air furnace is equipped for use with natural or propane gas at altitudes 0 - 10,000 ft (0 - 3,050m).
This furnace is for indoor installation in a manufactured (mobile) or modular home.
This furnace may be installed on combustible flooring in alcove or closet at minimum clearance from combustible material.
This appliance requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC,
PVC-DWV, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be installed is
maximum 24 inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials).

MINIMUM INCHES CLEARANCE TO

COMBUSTIBLE CONSTRUCTION

*

Mimimum front clearance for service 30 inches (762mm).

For installation on combustible floors only when installed on special base No. KGASB0201ALL,

Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.

Clearance in inches

This furnace is approved for
DOWNFLOW installation.

*

B

O

TTO

M

0"

3"

0"

0"

T

O

P/

PL

E

N

U

M

1"

0"

30

MIN

DOWNFLOW POSITION:

S I

D E

F

R

O

N

T

B

C

K

A

S

E

R V

I

E

C

F R

ON

T

S I

D E

U

F

R N

A C

E

This furnace must be installed in accordance with the manufacturer's instructions and Manufactured

Home Construction and Safety Standard, Title 24 CFR, Part 3280 or, when such standard is not

applicable, the ANSI A225.1, Standard for Manufactured Home Installation (Manufactured Home Sites,

Communities and Set-Ups), or the Mobile Homes Standard CAN/CSA-Z240 MH Series-M86.

This furnace must be installed with a direct vent (combustion air and flue) system, and use a factory

accessory termination kit.

324997-201 REV. A / LIT

1. All tubing must be connected securely and routed to avoid kinks and traps.

NOTE:

COLLECTOR BOX

DRAIN TUBE

CONDENSATE TRAP

INDUCER HOUSING

DRAIN TUBE

UPPER COLLECTOR BOX

PRESSURE TUBE

COLLECTOR BOX

DRAIN TUBE

DRAIN TUBE

COUPLING

INDUCER HOUSING

DRAIN TUBE

Condensate Trap

on LEFT Side

Condensate Trap

on RIGHT Side

GAS VALVE

CONDENSATE TRAP

COLLECTOR BOX EXTENSION DRAIN

TUBE

LOWER COLLECTOR BOX

PRESSURE TUBE

CAP / PLUG

DRAIN TUBES ROUTED IN

FRONT OF GAS VALVE

UPPER COLLECTOR

BOX PRESSURE TUBE

GAS VALVE

CAP / PLUG

LOWER COLLECTOR

BOX PRESSURE TUBE

BURNER ENCLOSURE

PRESSURE

REFERENCE TUBE

ASSEMBLY

BURNER ENCLOSURE

PRESSURE REFERENCE

TUBE ASSEMBLY

MANUFACTURED MOBILE HOME STANDARDS

TUBE ROUTING

Furnace must be installed level, or pitched forward within 1/2 inch of level for proper drainage. Failure will result
in equipment or property damage.

FRONT

1/2" MAX

TO

LEVEL (0")

DOWNFLOW