Bloomfield 8792 User Manual

Page 12

Advertising
background image

TROUBLESHOOTING SUGGESTIONS

10

SUGGESTED REMEDY

Check power supply cord
Check / reset circuit breaker


Set for desired temperature


Allow to cool
Reset hi-limit (8786, 8788)


Examine wiring & connectors,
thermostat and heating element
Repair/replace as needed


Be sure to add sufficient water
(see pg. 6 START-UP)


Increase water amount


Adjust amount of grounds


Adjust timer



Use one (1) genuine Bloomfield
filter per brew


Thoroughly clean brew chamber


Adjust coffee amount and grind



Check/reinstall gasket on
INSIDE of brew head


Clean spray disk


Turn water supply ON


Clean strainer


Replace filter element


Replace switch


Examine wiring & connectors,
brew switch and solenoid
Repair/replace as needed


Turn faucet valve ON


Disassemble faucet, clean


Adjust water temp 195-205ºF

POSSIBLE CAUSE

Brewer unplugged or circuit
breaker tripped


Thermostat set too low


Hi-Limit thermostat tripped


Damaged internal component or
wiring


Pourover - no water or too little
water added at startup


Not enough water poured in


Too much coffee grounds


Timer out of adjustment


Too many filter papers or wrong
filter paper


Brew chamber dispense hole
plugged


Too much coffee or too fine a
grind


Spray gasket improperly
installed


Spray disk plugged


Water supply OFF


Solenoid strainer plugged


Water filter (if used) plugged


Bad BREW switch


Damaged internal component
or wiring


Faucet valve turned OFF


Faucet plugged


Water not hot enough

SYMPTOM

Water won’t heat











Coffee level low (pour-over)


Coffee level too high or low
(automatic)


Brew chamber overflows






Sprays water from brew head



No brew (automatic)








No flow from hot water faucet


Poor coffee quality

Keep brewer, airpots and servers clean. Install a taste and odor
filter in water supply, and replace cartridges regularly.
Use a quality coffee with a consistent roast. Use proper grind and
amount of coffee per brew.

625

75873

Owner

s M

anual G

ourmet

1000 Dual

Airpo

t Br
ewers

Advertising