Prepare the installation location, Prepare the blower, Roof installations wall installations – Best EB6 User Manual

Page 3: All installations

Advertising
background image

3

11" dia.

hole

29½"

11" dia.

hole

1¼"

dia. hole

12

7

/

8

"

10¾"

25"

7¼"

7¼"

1¼"

dia. hole

9

1

/

8

"

9

1

/

8

"

W

a

ll

S

tu

d

10¾"

24¾"

28¼"

W

a

ll Stud

12

7

/

8

"

W

a

ll

S

tu

d

W

a

ll Stud

REMOVE

SIDING

REMOVE

SIDING

8½"

8½"

Pilot

Pilot
Hole

Hole

Pilot
Hole

OUTSIDE - WALL VIEW

OUTSIDE - WALL VIEW

1. Choose a position on the outside wall.

Make sure that no wall studs, pipes or

wires run through the opening area.

20½"

11"

dia.

hole

20½"

10

3

/

8

"

1¼"

dia. hole

10

3

/

8

"

8½"

8½"

20¾"

20¾"

7¼"

7¼"

1¼"

dia. hole

9

1

/

8

"

9

1

/

8

"

REMOVE

SHINGLES

Roof Rafter

REMOVE

SHINGLES

11"

dia.

hole

Roof Rafter

Pilot

Pilot
Hole

Hole

Pilot
Hole

OUTSIDE - ROOF VIEW

OUTSIDE - ROOF VIEW

1. Locate the blower on the rear slope of the

roof. Place it in a location to minimize

duct run. The location should be free of

obstacles (T.V. leads, electrical lines,

etc.). Bear in mind, if the blower top is

level with the roof peak, it will not be seen

from the street. Keep this approximate

location in mind as you work from within

the attic.

PREPARE THE
INSTALLATION LOCATION

ROOF INSTALLATIONS

WALL INSTALLATIONS

5. For flat roof installations, build a curb that

will mount the blower at a minimum pitch of

2/12. See Figure 2. Discharge end of the

blower should be pointed away from pre-

vailing winds.

Figure 2

Figure 1

From inside the attic space:
2. Drill a PILOT HOLE up through the roof,

8½" from the inside edge of a ROOF
RAFTER

.

From outside - on the roof:
3. Measure and mark the 20¾" x 20½" rect-

angle. Cut and remove only the shingles

inside this rectangle.

4. Measure and mark the 11" DIAMETER

HOLE

and the 1¼" DIAMETER HOLE.

Cut these holes all the way through the

roof.

PREPARE THE BLOWER

ALL INSTALLATIONS

1. Unpack the blower assembly.
2. Remove the cover and screws.
3. Remove and discard cardboard from blower

wheel.

4. Remove the wiring box cover and screws.
5. Attach an appropriate U.L. approved cable

connector in the hole at the rear of the wiring

box.

PREPARE THE
INSTALLATION LOCATION

Figure 3

From inside the wall:
2. Drill a PILOT HOLE through the wall, 8½"

from the inside edge of a WALL STUD.

From outside - on the wall:
3. Measure and mark the 24¾" x 28¼"

rectangle. Cut and remove only the sid-

ing inside this rectangle.

4. Measure and mark the 11" DIAMETER

HOLE

and the 1¼" DIAMETER HOLE.

Cut these holes all the way through the

wall.

6¾"

2"

28¼"

24¾"

2"

Advertising
This manual is related to the following products:

EB9