LEGEND

W2

Second-Stage Heat

Y2

Second-Stage Compressor

RS2

Second Remote Sensor (Not Used)

RS+5

+5 vdc for 2 Sensors

RS1

Remote Sensor

RS GND — Ground for 2 Sensors

W1/O/B

First-Stage Heat or Reversing Valve

Y1

First-Stage Compressor

G

Fan

W3/ECO — Third-Stage Heat or Economizer (Not Used)
CK1

Dry Contact

CK2

Dry Contact Ground

R

24 vac Transformer

C

24 vac Transformer Common

Fig. 2 — Thermostat Wiring

W2

TYPICAL
UNIT

L

C

G

Y1

E

O

W1

R

Y2

24 VAC COMMON

FAN RELAY

COMPRESSOR RELAY

1st STAGE HEAT CIRCUIT

24 VAC RETURN

2nd STAGE HEAT CIRCUIT

W2 Y2 R W1 Y1 G

C

THERMOSTAT

B

O

Fig. 3 — Typical Wiring (Single-Stage Cooling Units)

W2

TYPICAL
UNIT

L

C

G

Y1

E

O

W1

R

Y2

24 VAC COMMON

FAN RELAY

COMPRESSOR RELAY

1st STAGE HEAT CIRCUIT

24 VAC RETURN

2nd STAGE COMPRESSOR RELAY

2nd STAGE HEAT CIRCUIT

W2 Y2 R W1 Y1 G

C

THERMOSTAT

B

O

Fig. 4 — Typical Wiring (Two-Stage Cooling Units)

Table 1 — Thermostat Wiring Terminations

EXISTING

WIRE

DESIGNATION

FUNCTION

TERMINAL

CONNECTION

G or F

Fan

G

Y1, Y, or C

Cooling

Y1

W1, W, or H

Heating

W1/O/B

Rh, R, M, Vr, or A

Power (24 v)

R

C

Common

C*

O/B

Reversing Valve

W1/O/B†

Y2

Second Stage Cooling

Y2*

W2

Second Stage Heating

W2*

RS+5

Remote Sensor (5 vdc)

RS+5

RS

Remote Sensor Signal

RS1

RS G

Remote Sensor Ground

RS GND

CK1

Dry Contact Switch

CK1

CK2

Dry Contact Ground

CK2

*Terminals C, Y2, and W2 may not be used in all applications.

†Used on Heat Pump applications only.

—3—