Step 4: Connecting supply and drain

1. Connect the Vernatherm™ Thermostatic Mixing Valve as shown in Figure 5a.

2. Install the drain plug in the drain hole in the bowl (see Figure 5b).

3. Beneath the bowl, install the 1/8" rubber washer and the threaded tailpiece onto the drain plug.

4. Assemble the P-trap by connecting the 1-1/2" tubular pipe to the tailpiece and to the 1-1/2" drain

pipe stubbed out of the wall (see Figure 5c).

5. Install the strainer on the drain plug opening inside the bowl using the #8 screw.

P-TRAP

STRAINER

TAILPIECE

FRAME (FRONT)

45˚

Figure 5c

VERNATHERM™

BRACKET

#10 SCREW

VERNATHERM™

VALVE

1/2" FLEXIBLE

HOSE

CHECK/STOP

VALVE

1/2" NPT

COLD SUPPLY

HOT SUPPLY

H

C

Figure 5a

Figure 5b

STRAINER

BOWL

1/8"
RUBBER
WASHER

DRAIN

PLUG

TAILPIECE

#8 SCREW