Internal tank manual refill, 8 internal tank manual refill – Bacharach 2072-0400 User Manual

Page 29

Advertising
background image

MAC2000

Operation

Total Flush ........Time spent flushing and number of times it was

performed

Recovered .........Total amount of refrigerant recovered
Charged ............Total amount of refrigerant charged
Added ................Total amount of refrigerant transferred from the

external virgin tank to the internal storage tank

Filter life left .....Weight of refrigerant that can be charged before

the Filter Dryer needs replaced

Pressing Next again displays the “Job history” screen, which
contains the history of each job performed. A technician can press the
UP

and Down keys to scroll through the last 75 jobs.


Tips:

Holding down the Up or Down key speeds up scrolling.


The total screen can be cleared by entering the Set-up mode and
selecting “Clear totals?

Job history can be cleared by entering the Set-up mode and selecting

Clear job history?


3.8 Internal Tank Manual Refill


When the MAC2000 remains turned ON during the day, the unit
automatically refills the internal tank with refrigerant from the
external source tank. An operator, however, can manually add
refrigerant as follows:

1.

If not already done, plug the MAC2000 into a properly grounded
AC outlet; set the Power switch to ON; then wait until the unit
completes its self diagnostics. The screen will display “Select
mode
” when ready.

2.

Press the Next menu function key to display Menu 2. Then press
the Tank refill function key to begin the refill process.

Note:

If the tank is already filled with 12 lbs or more of refrigerant,

then the message “Tank already full” appears.

3.

Press the Start key to continue. The screen will then display “The
internal tank is now being refilled
.” When the internal tank is
filled, the screen displays “Tank refill complete.

4.

Press the Reset key to return to the Main menu.




Instruction 2072-0400